CASH ACME
CASH ACME 17148 Vacuum Breaker 3/4 in FNPT Brass
3/4 in FNPT brass vacuum breaker rated 125 psi with ASSE 1011 and CSA B 64.2 compliance
- Size3/4"
- TypeTraffic & Parking Lot
- Prevents backflow with ASSE 1011 certified vacuum breaker
- Handles 125 psi maximum pressure for reliable operation
- Operates from 0 to 180 Degrees F temperature range
- Durable brass construction with Buna Nitrile seal
- Compact 1 5/16 in height fits tight spaces
3/4 in Brass Vacuum Breaker
The CASH ACME 17148 vacuum breaker installs on 3/4 inch FNPT connections to prevent back-siphonage in potable water lines. Its brass body and Buna nitrile seal meet ASSE 1011 and CSA B64.2 standards for cross-connection control. The unit suits residential and commercial plumbing systems requiring atmospheric venting.
125 psi pressure rating and 180 °F limit
Rated for a maximum pressure of 125 psi, the breaker handles typical municipal supply pressures with adequate headroom. The temperature range of 0 to 180 degrees Fahrenheit covers standard hot water distribution. Systems exceeding either limit will require a different protection device.
Replaces worn atmospheric vent valves
This breaker replaces failed or code-noncompliant vacuum breakers on hose bibbs, irrigation taps or utility sinks. The upgrade is worth it when inspection demands ASSE 1011 compliance or when the original valve leaks under back-pressure. It does not serve continuous-pressure applications or high-hazard containment needs.
Highlights
- Prevents backflow with ASSE 1011 certified vacuum breaker
- Handles 125 psi maximum pressure for reliable operation
- Operates from 0 to 180 Degrees F temperature range
- Durable brass construction with Buna Nitrile seal
- Compact 1 5/16 in height fits tight spaces
Specifications
| Brand | CASH ACME |
|---|---|
| Size | 3/4" |
| Type | Traffic & Parking Lot |
Questions about this item
Will the 3/4 in FNPT brass vacuum breaker thread onto my existing GHT hose bibb?
The unit has a 3/4 in FNPT inlet and a GHT outlet, so it screws directly onto a standard garden-hose thread bibb without an adapter.
How can I confirm the breaker is venting correctly once installed?
Open the supply; water should flow freely. Shut off the downstream valve — the internal check should close and the vent port must release any back-siphonage, showing the ASSE 1011 device is functioning.
Does the 17148 package include a replacement Buna-N seal or mounting hardware?
The breaker ships assembled with its Buna-N seal installed; no extra seals, washers or mounting brackets are supplied in the box.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.