Cable Leader
Cable Leader 8ft C14 to C19 14 AWG 15A 250V Black Power Extension Cord
An 8 ft C14-to-C19 extension adds reach between PDU, UPS or server and existing cord, using 14 AWG 15 A 250 V SJT copper that is UL Listed and CSA certified
- ColorBlack
- Length5 - 10 ft.
- Connector Number2
- Wire Gauge14 AWG
- Extends C14-to-C19 reach by 8 ft between PDU and server
- Heavy-duty 14 AWG copper handles 15 A at 250 V for rack loads
- SJT jacket rated 105 °C / 300 V withstands data-centre heat
- UL Listed and CSA certified (file E210037), RoHS compliant
- Black jacket simplifies circuit and phase identification in the rack
Extends C14-to-C19 Power Reach
This eight-foot cord adds length between a rack PDU, UPS or server and an existing C19-terminated power cord. The male IEC 60320 C14 plug connects to the power source while the female C19 socket accepts the equipment cord, removing the need for a separate adapter. It suits data-centre racks, server rooms and AV installations that use standard IEC 60320 connectors.
Heavy-Duty 14 AWG Construction
Three-conductor grounded copper at 14 AWG is rated for 15 A at 250 V, with an SJT jacket rated to 105 °C and 300 V. The gauge supports higher-draw equipment such as servers and PDUs, whereas lighter 18 AWG or 16 AWG cords are limited to 10 A or 13 A respectively. The black jacket aids visual circuit tracing in dense rack environments.
Safety-Certified for Continuous Use
UL Listed and CSA certified under file E210037, the cord meets RoHS requirements for hazardous-substance compliance. The robust SJT sheathing and grounded conductors maintain safe operation under sustained server loads without excess heat or voltage drop. Not intended for 20 A circuits that require 12 AWG or for devices using non-IEC connector types.
Highlights
- Extends C14-to-C19 reach by 8 ft between PDU and server
- Heavy-duty 14 AWG copper handles 15 A at 250 V for rack loads
- SJT jacket rated 105 °C / 300 V withstands data-centre heat
- UL Listed and CSA certified (file E210037), RoHS compliant
- Black jacket simplifies circuit and phase identification in the rack
Specifications
| Brand | GENERIC |
|---|---|
| Color | Black |
| Length | 5 - 10 ft. |
| Connector Number | 2 |
| Wire Gauge | 14 AWG |
Questions about this item
What is the continuous current limit for the 14 AWG conductors on this cord?
The 14 AWG, 3-conductor copper is rated for 15 A at 250 V, so sustained loads must stay at or below 15 A.
How warm does the SJT jacket get when the cord carries a full 15 A load all day?
The jacket is rated to 105 °C, so under continuous 15 A operation the surface temperature can approach that limit inside a warm rack.
What mating connector must already be on the equipment cord to plug into the female C19 end?
The equipment cord needs a male IEC 60320 C19 plug to mate with the C19 socket on this extension.