We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Cable Leader

Cable Leader 8 ft NEMA L6-30P to C19 Locking Power Cord 12 AWG SJT 10A/125V Black

SKU CH-DWQM-2CJAD

An 8 ft twist-lock cord connects a locking NEMA L6-30P outlet to a C19 inlet using 12 AWG SJT cable rated 10A at 125V

  • ColorBlack
  • Length5 - 10 ft.
  • Connector Number2
  • Wire Gauge12 AWG

Length 8ft

  • Twist-lock plug prevents accidental disconnection in racks
  • 12 AWG copper handles up to 20 A loads
  • SJT jacket rated 105 °C and 300 V
  • UL Listed and CSA certified file E210037
  • Black jacket simplifies circuit identification in data centres

Locking Server Power Cord

The Cable Leader 8 ft NEMA L6-30P to C19 cord provides a twist-lock connection that secures servers, PDUs and rack equipment to a locking outlet in data centres and server rooms. The plug cannot be pulled loose by vibration or accidental tugging.

12 AWG Current Capacity

The cord uses 12 AWG three-conductor copper rated at 10 A and 125 V with an SJT jacket certified to 105 °C and 300 V. That gauge supports up to 20 A for heavy-duty equipment, so it suits 20 A circuits rather than lighter 10 A or 15 A loads.

Sustained Rack Operation

Under continuous load the SJT jacket maintains its temperature rating and the locking plug keeps the circuit intact without intermittent contact. It is built for always-on infrastructure where an unplanned disconnection would interrupt service.

Highlights

  • Twist-lock plug prevents accidental disconnection in racks
  • 12 AWG copper handles up to 20 A loads
  • SJT jacket rated 105 °C and 300 V
  • UL Listed and CSA certified file E210037
  • Black jacket simplifies circuit identification in data centres

Specifications

BrandGENERIC
ColorBlack
Length5 - 10 ft.
Connector Number2
Wire Gauge12 AWG

Other versions of this model

3 more in the same range

Same family, different memory, cooler or clock — compare before you commit.

Questions about this item

What does the 12 AWG rating mean when the cord is powering a server in a rack?

The 12 AWG copper conductors support up to 20 A for heavy-duty equipment, so the cord can carry the full rated load without overheating in a server or PDU installation.

How does the NEMA L6-30P twist-lock plug limit what outlets I can use?

The L6-30P locking plug only mates with a matching NEMA L6-30R receptacle, so the cord works exclusively with 30 A locking outlets found in data-centre PDUs and rack power strips.

What clearance do I need behind the rack for the 8 ft cord and its connectors?

The cord is 8 ft long with a twist-lock L6-30P plug on one end and a C19 connector on the other; allow enough depth for the locking collar and the C19 hood to seat fully without bending the SJT jacket sharply.