We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
C2G Canada
Slim Cat6 UTP patch cable with 28 AWG conductors reduces diameter by 36% for better airflow and easier routing in dense installations
This C2G Cat6 UTP patch cable measures 15 ft (4.57 m) and uses 28 AWG conductors for a slim profile. The reduced diameter is 36% smaller than a standard Cat6 patch cable. A moulded snagless boot prevents the connector tabs from catching during installation. It is intended for bandwidth-intensive voice, data or video distribution.
Installers working in crowded patch panels or datacentre cabinets benefit from the smaller bend radius and improved airflow. Buyers who need a cable that complies with the ANSI/TIA-568-C.2 conductor-size recommendation of 22-26 AWG should choose a standard-gauge Cat6 cable instead. The higher attenuation of 28 AWG also makes it unsuitable for runs that require the full certified channel length.
The single specification that determines whether this cable is the right part is the 28 AWG conductor size. It delivers the slim diameter and tight bend radius needed for dense installations, but it does not meet the 22-26 AWG requirement of the ANSI/TIA-568-C.2 standard and exhibits increased attenuation.
No published specifications for this item yet.
The 28 AWG conductors give this cable a smaller bend radius and 36% reduced diameter versus standard Cat6, so it bends easily through tight panels; push the connector straight in rather than rocking the boot to avoid stress on the latch.
Yes, the smaller 28 AWG conductors increase attenuation and do not meet the ANSI/TIA-568-C.2 conductor-size recommendation, so plan to re-certify or replace runs if link margins drop below your switch requirements.
At 15 ft the added attenuation from 28 AWG is still within typical 1 Gbps channel budgets, but the cable is not ANSI/TIA-568-C.2 compliant for permanent links, so the gauge limit appears first on longer permanent runs rather than this short patch.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?