We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Belkin

Belkin BE107200-06 6 ft 7-outlet 2320 J surge protector

SKU CH-HCEC-PZQ5M MPN BE107200-06

Seven surge-protected outlets with a 2320-joule rating and six-foot cord shield home and office electronics

  • Outlets7
  • Cord Length6 Feet
  • Input Voltage125V
  • Output Amperage Capacity15
  • Output Watt Capacity1875 Watts
  • AC Suppression Joule Rating2320 joule
  • 2320-joule rating protects sensitive electronics from damaging spikes
  • Seven surge-protected outlets handle multiple devices on three AC lines
  • 6-foot right-angle cord reaches distant sockets without blocking adjacent plugs
  • EMI/RFI filter cuts noise up to 43 dB for cleaner power delivery
  • Data-line RJ-11 protection shields phone, modem, fax or DSL connections

What this surge protector powers

The Belkin BE107200-06 provides seven surge-protected outlets for home or office electronics. A 2320-joule rating and 330-volt clamping voltage guard connected devices across hot-neutral, neutral-ground and hot-ground lines. The 6-foot right-angle cord reaches wall sockets behind furniture. It suits desktop computers, monitors, routers and phone-line equipment needing AC and RJ-11 protection.

Heat noise and power in daily use

The strip runs at 125 volts with a 15-ampere, 1875-watt capacity for typical office loads. An EMI/RFI filter covers 150 kHz to 100 MHz with up to 43 dB attenuation to reduce line noise. Overload protection and a safety shutdown circuit cut power when current exceeds the rated limit. A red NOT GND indicator lights if the wall outlet lacks a proper ground connection.

What the bundled features change

Two RJ-11 ports (one in, two out) shield telephone, modem, fax or DSL lines from surges entering through data cables. Integrated cord management keeps the six-foot cable and connected leads tidy. A connected-equipment warranty up to $100k covers attached devices if the protector fails. No software or extra accessories are included beyond the strip itself.

Highlights

  • 2320-joule rating protects sensitive electronics from damaging spikes
  • Seven surge-protected outlets handle multiple devices on three AC lines
  • 6-foot right-angle cord reaches distant sockets without blocking adjacent plugs
  • EMI/RFI filter cuts noise up to 43 dB for cleaner power delivery
  • Data-line RJ-11 protection shields phone, modem, fax or DSL connections

Specifications

BrandBELKIN
SeriesHome/Office
ModelBE107200-06
Outlets7
Cord Length6 Feet
Input Voltage125V
Output Amperage Capacity15
Output Watt Capacity1875 Watts
AC Suppression Joule Rating2320 joule
EMI/RFI Noise Filter150K Hz -100M Hz, up to 43dB
Clamping Voltage330 Volts
Protection ModesH-N, N-G and H-G
Data Line ProtectionRJ-11 Telephon / Modem / Fax / DSL protection (1 in, 2 out)
ColorBlack
SpecificationMax. Spike Voltage: 6000V
AC Plug Style: Right Angle
NOT GND Indicator: Yes, RED
Overload Protection: Yes
Power Safety Shut Down: Yes
Features2320 joule energy rating provides maximum protection of all your sensitive electronic devices
7 Surge-protected outlets supply complete, 3-line AC protection
6-foot power cord delivers optimal, safe AC power through a 14-gauge heavy-duty cord
Filters EMI / RFI noise up to 43dB reduction
1-in, 2-out RJ11 Telephone / Fax Surge Protection
Right angle plug
Unit Dimensions13.60" x 3.30" x 2.36"
Unit Weight1.23 lbs.
Shipping weight0.66 kg
Package size376 × 124 × 56 mm

Questions about this item

How do I install the Belkin BE107200-06 and what is the common mistake with the right-angle plug?

Plug the right-angle AC plug into a grounded 125V wall socket, route the 6-foot cord using the cord management clips, then connect devices to the seven surge-protected outlets. The step people miss is verifying the red NOT GND indicator stays off; if it lights, the outlet lacks a proper ground and protection is compromised.

What maintenance or replacement will the Belkin BE107200-06 need over time?

The 2320-joule MOV array degrades with each surge event. Replace the unit after a major spike or when the protection indicator (if present) signals end of life. No user-serviceable parts exist; the RJ-11 pass-through (1 in, 2 out) requires no upkeep beyond checking cable seating.

What limit appears first on the Belkin BE107200-06 during sustained heavy load?

The 15-amp / 1875-watt thermal overload breaker trips before the 2320-joule surge capacity or 330-volt clamping voltage are reached. Continuous draw above 15 amps shuts power down via the safety shutdown feature, protecting downstream gear and the unit itself.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.