We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

ATEN

ATEN PE8108A Monitored 8-Outlet 15A/10A PDU

SKU CH-A3WN-9HQ8N

Monitored 8-outlet PDU with real-time power measurement and remote TCP/IP control for 100–120V rack equipment

  • TypeMonitored
  • Package Includes1 x PE8108A Power Distribution Unit 1 x Power Cord 1 x Rack
  • Input Voltage100 - 120V
  • Input Frequency50/60 Hz
  • Input Connector(s)1 x IEC 320 C20
  • Cord Length10 ft
  • Monitored 8-outlet PDU enables remote power management
  • 15 A capacity with UL derated 12 A rating
  • 10 ft IEC C20 input cord for flexible rack placement
  • Real-time outlet-level power measurement via TCP/IP
  • 1U 17-inch rackmount fits standard server cabinets

Monitored 8-Outlet PDU for Server Racks

The ATEN PE8108A is a monitored power distribution unit with eight NEMA 5-15R outlets rated at 15A (UL derated 12A) or 10A. It provides remote power control and real-time outlet-level power measurement for servers, storage, and network gear in data centres. The unit includes a 10 ft cord with an IEC 320 C20 input plug and rack-mount hardware.

Check Input Voltage and Outlet Type Before Ordering

Your facility must supply 100-120V at 50/60 Hz to match the PDU input and output ratings. Verify that the IEC C20 inlet matches your upstream power source or UPS outlet. Confirm that connected equipment uses NEMA 5-15P plugs and that total load stays within the 12A derated limit for UL compliance.

Replaces Basic Power Strips Without Monitoring

This unit upgrades from unmonitored rack strips by adding TCP/IP remote switching and per-outlet energy data. The jump is worth it when you need to reboot hung servers remotely, track power consumption for capacity planning, or integrate with SNMP v3 management software and eco Sensors for environmental alerts.

Highlights

  • Monitored 8-outlet PDU enables remote power management
  • 15 A capacity with UL derated 12 A rating
  • 10 ft IEC C20 input cord for flexible rack placement
  • Real-time outlet-level power measurement via TCP/IP
  • 1U 17-inch rackmount fits standard server cabinets

Specifications

BrandATEN
ModelPE8108A
TypeMonitored
Package Includes1 x PE8108A Power Distribution Unit
1 x Power Cord
1 x Rack Mount Kit
1 x Software CD
1 x User Instructions
Input Voltage100 - 120V
Input Frequency50/60 Hz
Input Connector(s)1 x IEC 320 C20
Cord Length10 ft
Output Voltage100 - 120V
Output Frequency50/60Hz
Output Connector(s)8 x NEMA 5-15R
Operating Environment0 - 50 degrees C
Operating Relative Humidity0 - 80%
Storage Temperature-20 - 60 ºC
Features8 outlets
15A (UL derated 12A) / 10A
Outlet Power Measurement
The PE8108 eco PDU is intelligent PDUs that contains 8 AC outlets and is available in various IEC or NEMA socket configurations. It provides secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors.
Dimensions1.70" x 17.00" x 8.60"
Weight6.20 lbs.

Questions about this item

Does the box include everything needed to rack-mount and power the PE8108A, or must I buy a separate cord or brackets?

The package includes the PDU, a 10 ft power cord with an IEC 320 C20 plug, a rack-mount kit, a software CD and user instructions.

Should I choose the 15 A UL derated 12 A rating or the 10 A rating for my 100-120 V installation?

The unit is rated 15 A with a UL derated 12 A limit for North American use and 10 A for other regions; select the rating that matches your local code and circuit breaker.

What does the 15 A / 12 A derated figure mean for actual outlet load on a 120 V circuit?

On a 120 V circuit the PDU can supply up to 12 A total across its eight NEMA 5-15R outlets, with per-outlet measurement for monitoring each device's draw.