We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC SURTA1500RMXL2U 1500VA 1050W 2U Rack Tower UPS

SKU CH-8NGQ-0DNT4 MPN SURTA1500RMXL2U

Rack-tower UPS delivering 1500 VA and 1050 W with six NEMA 5-15R outlets, USB and serial management, and 8.60 minutes runtime at full load

  • Input Voltage Range90 - 150V
  • Input Frequency50/60 Hz +/- 5 Hz (auto sensing)
  • VA Rating1500 VA
  • Watts1050 Watts
  • Output Voltage120V
  • Outlets6
  • 1050 W output handles heavy server loads
  • 1500 VA capacity keeps critical gear running longer
  • 2U rack height fits dense server cabinets
  • USB, RS-232 and Smart-Slot enable remote management
  • 540 J surge rating shields connected equipment from spikes

Rack Tower UPS 1500VA 1050W

The APC SURTA1500RMXL2U is a 2U rack tower uninterruptible power supply rated at 1500 VA and 1050 W. It provides battery backup and surge protection for servers, networking gear and workstations in 120 V environments. Six NEMA 5-15R outlets distribute conditioned power to connected equipment.

Extended runtime under full load

At full 1050 W load the unit delivers approximately 8.60 minutes of backup time, allowing orderly shutdown of critical systems. The battery recharges to usable capacity within three hours after a discharge event. Audible alarms signal battery operation, low battery condition and overload states for immediate operator awareness.

540 Joule surge rating and 90-150 V input window

Surge energy absorption is rated at 540 Joules, limiting transient voltage passed to attached devices. The input voltage range of 90 to 150 V accommodates significant mains variation without transferring to battery. Management interfaces include DB-9 RS-232, USB and a Smart-Slot for optional network cards.

Highlights

  • 1050 W output handles heavy server loads
  • 1500 VA capacity keeps critical gear running longer
  • 2U rack height fits dense server cabinets
  • USB, RS-232 and Smart-Slot enable remote management
  • 540 J surge rating shields connected equipment from spikes

Specifications

BrandAPC
ModelSURTA1500RMXL2U
Input Voltage Range90 - 150V
Input Frequency50/60 Hz +/- 5 Hz (auto sensing)
VA Rating1500 VA
Watts1050 Watts
Output Voltage120V
Outlets6
Outlet TypeNEMA 5-15R
AlarmsAlarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Interface PortDB-9 RS-232,Smart-Slot,USB
ApprovalsBSMI,CSA,FCC Part 15 Class B,UL 1778
Rackmountable2U
Surge Energy Rating540 Joules
FeaturesReceptacles: 6 x NEMA 5-15RLoad Capacity (VA): 1500 VALoad Capacity (Watt): 1050 WInput Voltage: 110 V ACOutput Voltage: 120 V ACBackup/Run Time (Full Load): 8.60 MinuteMaximum Battery Recharge Time: 3 HourHeight: 3.4" (85.1 mm)Width: 17" (431.8 mm)Depth: 22" (558.8 mm)Rack Height: 2UForm Factor: Tower/Rack MountableWeight (Approximate): 27.44 kgPackage Contents: Smart-UPS RT 1500VA Tower/Rack-mountable UPSCD with softwareDocumentation CDRack Mounting support railsSmart UPS signalling RS-232 cableUSB cableUser Manual1 x Battery ModuleLimited Warranty: 2 Year
Weight73.3
Package Contents90615L
Shipping weight31.30 kg
Package size737 × 610 × 260 mm

Questions about this item

How much heat does the 1050 W UPS generate when running continuously?

The unit draws up to 1500 VA at 120 V, so sustained operation produces heat proportional to that load; ensure the rack or tower location has adequate airflow.

Which cables or cards must I already have to use the DB-9 RS-232, Smart-Slot or USB management ports?

A DB-9 RS-232 cable and a USB cable are included; the Smart-Slot accepts optional APC management cards purchased separately.

Will my older 120 V servers with NEMA 5-15P plugs connect directly to the six NEMA 5-15R outlets?

Yes, the six NEMA 5-15R receptacles accept standard NEMA 5-15P plugs used by legacy 120 V equipment.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.