We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC SRT5KXLTUS 5000VA 208V 3U Rack/Tower UPS

SKU CH-7P3B-SGW2C MPN SRT5KXLTUS

A 5000 VA rack/tower UPS with 208 V input, 4250 W capacity, 4.4 minutes runtime at full load and TAA compliance

  • TAA-compliant UPS assembled in the USA for government and regulated deployments
  • 5000 VA / 4250 W capacity supports dense server and network loads
  • 208 V nominal input with 160–275 V range tolerates unstable utility power
  • Convertible 3U rack/tower form factor fits standard racks or floor placement
  • Smart-UPS intelligence enables network management of servers, switches and POS devices

Rack/Tower UPS for Network Infrastructure

The APC SRT5KXLTUS is a 5000 VA, 4250 W double-conversion UPS designed to protect servers, routers, switches and point-of-sale equipment. It operates from a 208 V AC source and delivers 230 V AC output through two L6-30R and two L6-20R receptacles. The unit fits a 3U rack space or stands as a tower.

Upgrade from Basic Standby Units

This model replaces single-conversion or standby UPS hardware when continuous voltage regulation and zero transfer time are required. The jump is justified for loads that cannot tolerate any interruption or voltage deviation, such as active network cores or transactional databases. At full 4250 W load the battery provides 4.40 minutes of runtime to allow graceful shutdown.

Limits of 3U Form Factor and Input Range

The 3U chassis measures 17 inches wide, 5.1 inches high and 28.3 inches deep, weighing approximately 123 lb, which constrains rack density and requires adequate floor or shelf support. Input voltage tolerance spans 160 V to 275 V AC; sources outside this window will not be conditioned. Battery recharge takes 1.50 hours after a full discharge.

Highlights

  • TAA-compliant UPS assembled in the USA for government and regulated deployments
  • 5000 VA / 4250 W capacity supports dense server and network loads
  • 208 V nominal input with 160–275 V range tolerates unstable utility power
  • Convertible 3U rack/tower form factor fits standard racks or floor placement
  • Smart-UPS intelligence enables network management of servers, switches and POS devices

Specifications

BrandAPC by Schneider Electric
Shipping weight95.29 kg
Package size254 × 25 × 25 mm

Questions about this item

What rack depth and clearance does the 3U, 28.3-inch deep UPS require for installation?

The unit is 28.3 inches deep and 3U high; allow front and rear airflow clearance when mounting in a standard rack.

How do you connect the NEMA L6-30P input plug and which receptacles supply the load?

Wire the L6-30P plug to a 208 V, 30 A circuit; the UPS provides two L6-20R and two L6-30R outlets for connected equipment.

When and how should the internal battery be replaced?

Replace the battery after roughly 3 to 5 years or when runtime drops below 4.4 minutes at full load; recharge takes 1.5 hours after each discharge.