APC
APC SMX2200RMLV2U 2U Rack/Tower UPS 2200VA 1980W 16GB USB
2U rack/tower UPS delivers 2200VA/1980W pure sine wave power with AVR, eight NEMA 5-15R and two NEMA 5-20R outlets, SmartSlot and SmartConnect ports, plus a bundled 16GB USB 3.0 drive
- 2200 VA / 1980 W pure sine wave output protects critical IT loads
- 2U convertible rack/tower form fits server rooms or office shelves
- Automatic voltage regulation keeps output within selectable 100–127 V range
- Expandable runtime with up to 10 external battery packs (SMX120RMBP2U)
- Bundled 16 GB USB 3.0 drive included for documentation or firmware storage
2U Rack/Tower UPS for critical electronics
The APC SMX2200RMLV2U delivers 2200VA and 1980W of line-interactive pure sine wave power in a 2U convertible form factor. It targets IT managers and network administrators who need continuous power for servers and networking gear during prolonged outages. A bundled 16GB USB 3.0 drive is included in the package.
Fits standard racks and uses NEMA L5-30P input
The unit mounts in a 2U rack space measuring 3.35 inches tall, 17.00 inches wide and 26.26 inches deep, weighing 84.77 pounds. It connects to a NEMA L5-30P supply and provides eight NEMA 5-15R plus two NEMA 5-20R outlets for protected loads. Up to ten external battery packs can be added to extend runtime as needed.
Suits managers needing pure sine wave and AVR
Automatic Voltage Regulation with user-selectable 100V-127V output stabilises connected equipment against fluctuations. The SmartConnect port and SmartSlot allow remote monitoring and management card integration. Buyers who need a different input plug, higher wattage capacity or a smaller desktop form factor should evaluate other options.
Highlights
- 2200 VA / 1980 W pure sine wave output protects critical IT loads
- 2U convertible rack/tower form fits server rooms or office shelves
- Automatic voltage regulation keeps output within selectable 100–127 V range
- Expandable runtime with up to 10 external battery packs (SMX120RMBP2U)
- Bundled 16 GB USB 3.0 drive included for documentation or firmware storage
Specifications
No published specifications for this item yet.
Questions about this item
What load level triggers the first limit during sustained use?
The UPS delivers up to 1980 W or 2200 VA; exceeding that capacity will trip the overload protection and drop the load.
How loud and how hot does the unit get when it runs all day?
The 2U rack/tower chassis uses internal fans to move air through the 26.26 in depth; expect typical data-centre noise levels and warm exhaust air under continuous load.
What must I already own for this UPS to work out of the box?
A NEMA L5-30P 30 A branch circuit and a PDU or devices with NEMA 5-15R or 5-20R plugs are required to connect the eight 5-15R and two 5-20R outlets.