We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
APC
Rack-mountable on-line UPS delivering 2200 VA and 1800 W with six NEMA 5-20R and one NEMA L5-20R outlets
The APC Smart-UPS SRT 2200VA RM 120V is an on-line double-conversion uninterruptible power supply that delivers 2200 VA and 1800 W with unity power factor. It mounts in a 2U rack or tower form factor and includes a pre-installed network management card for remote monitoring. Six NEMA 5-20R outlets and one NEMA L5-20R outlet provide protected power for connected equipment.
This unit fits network closets, server rooms, retail offices, banking sites, medical labs and industrial applications that require continuous, clean power and remote management. It is not intended for desktop workstations or home offices that need only basic standby backup, nor for installations that cannot accommodate a 2U rack or tower footprint.
The on-line topology supplies full rated wattage equal to the VA rating, so the 2200 VA rating corresponds directly to 1800 W of usable power for servers and networking gear. The graphical LCD interface reports real-time status and diagnostics locally, while the network card enables integration with management platforms.
| Brand | APC |
|---|---|
| Model | SRT2200RMXLA-NC |
| Weight | 55.1000 |
Mount the 2U chassis using the included rail kit, then secure the front brackets. The step often missed is wiring the NEMA L5-20R input to a dedicated 20 A branch circuit before powering on.
Replace the internal battery cartridge every three to five years; the LCD interface will display a replacement warning when runtime drops below the 1800 W load threshold.
The 1800 W output rating is reached before the 2200 VA apparent-power rating, so real-power loads trigger overload protection first.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?