We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC Smart-UPS On-Line SRT6KXLT 6000 VA 208 V UPS

SKU CH-EJCD-HHHG6 MPN SRT6KXLT

Double-conversion on-line UPS delivering 6000 VA and 6000 W at 208 V with six outlets including hard-wire, NEMA L6-20R and L6-30R.

  • Input Voltage Range208V
  • Input Frequency45 - 65 Hz (auto sensing)
  • Input ConnectionHard Wire 3-wire (2PH + G)
  • VA Rating6000 VA
  • Watts6000 W
  • Output Voltage208V
  • True double-conversion topology protects critical loads from all power disturbances
  • 6000 VA and 6000 W capacity supports dense server racks and blade chassis
  • Six mixed outlets include hard-wire, L6-20R and L6-30R for flexible distribution
  • Hot-swappable APCRBC140 battery module enables replacement without downtime
  • Smart-Slot accepts management cards for remote monitoring and graceful shutdown

True double-conversion UPS for critical loads

The APC Smart-UPS On-Line SRT6KXLT delivers 6000 VA and 6000 W of continuous output at 208 V. It uses true double-conversion topology to isolate connected servers, network gear, medical equipment or light-industrial systems from every input disturbance. Hard-wire input and a mix of NEMA L6-20R and L6-30R outlets suit permanent three-phase installations. The unit is new and rated ENERGY STAR.

Battery performance at full load and recharge rate

At maximum rated load the internal battery provides approximately 2 minutes of runtime, a figure typical for double-conversion units sized for short bridging rather than extended operation. Recharge to full capacity takes 1.50 hours, so the UPS is ready for a second event quickly. Audible and visible alarms prioritised by severity give immediate warning of battery depletion or fault conditions without relying on software polling.

Smart-Slot interface for remote management

A single Smart-Slot bay accepts an optional network management card to add SNMP, web and environmental monitoring, which is the deciding factor for sites that need lights-out control. The bundled PowerChute software handles graceful unattended shutdown of network operating systems when the battery threshold is reached. Without a card installed the UPS operates standalone with local alarms only.

Highlights

  • True double-conversion topology protects critical loads from all power disturbances
  • 6000 VA and 6000 W capacity supports dense server racks and blade chassis
  • Six mixed outlets include hard-wire, L6-20R and L6-30R for flexible distribution
  • Hot-swappable APCRBC140 battery module enables replacement without downtime
  • Smart-Slot accepts management cards for remote monitoring and graceful shutdown

Specifications

BrandAPC
SeriesSmart-UPS On-Line
ModelSRT6KXLT
Input Voltage Range208V
Input Frequency45 - 65 Hz (auto sensing)
Input ConnectionHard Wire 3-wire (2PH + G)
VA Rating6000 VA
Watts6000 W
Output Voltage208V
Outlets6
Outlet Type(1) Hard Wire 3-wire (2PH + G)
(2) NEMA L6-20R
(3) NEMA L6-30R
Battery TypeSealed Lead Acid
Battery Recharge Time3 hour(s)
Battery ReplaceableAPCRBC140
AlarmsAudible and visible alarms prioritized by severity
Interface PortSmart-Slot
Management SoftwareYES
ApprovalsENERGY STAR (USA), FCC Part 15 Class A, UL 1778
Surge Energy Rating480 Joules
FeaturesAPC Smart-UPS On-Line,6000 Watts /6000 VA,Input 208V /Output 208V, Extended runtime model
Dimensions17.00" x 6.85" x 28.32" (H x W x D)
Weight135.00 lbs.
Package ContentsAPC Smart-UPS SRT6KXLT 6000VA 208V, CD with software, Documentation CD, Installation guide, Removable support feet, Temperature Probe, USB cable, User Manual, Warranty card
Shipping weight81.65 kg
Package size965 × 610 × 381 mm

Questions about this item

Does the SRT6KXLT run its fans continuously or only under heavy load?

The unit uses double-conversion topology with temperature-controlled fans; audible and visible alarms signal severity changes during extended operation.

What input wiring must the site provide for the hard-wire 3-wire (2PH + G) connection?

A 208 V, 45–65 Hz, two-phase-plus-ground supply with appropriate breaker and conduit is required for the hard-wire inlet.

Can I keep using existing NEMA L6-20R and L6-30R power cords with the six outlets on this UPS?

Yes — the rear panel provides two L6-20R and three L6-30R receptacles alongside the hard-wire output for legacy cords.