APC Smart-UPS On-Line 10kVA 208V 4x L6-20R 2x L6-30R UPS
A 10 kVA on-line UPS delivers pure sine-wave power at 208 V or 240 V with four L6-20R and two L6-30R outlets, an embedded network management card and a SmartSlot for optional accessories
- Pure sine wave protects sensitive equipment
- 10 kVA on-line topology delivers continuous power
- 70 minute standby at full load
- 50 hour recharge restores backup fast
- Network card plus SmartSlot enables remote management
10 kVA On-Line UPS for Critical IT Infrastructure
This double-conversion UPS delivers pure sine-wave output at 10 kVA and 10 kW to protect servers, storage arrays and network gear from any power disturbance. It mounts in a 2U rack space or stands as a tower and includes an embedded Network Management Card plus a free SmartSlot for optional accessories. PowerChute Network Shutdown software enables graceful shutdown of physical, virtual and hyper-converged workloads.
208/240 V Hard-Wired Input with Fixed Outlet Mix
The unit requires a hard-wired three-wire (2P+E) feed at 208 V or 240 V AC and cannot be plugged into a standard receptacle. Output is limited to four NEMA L6-20R and two NEMA L6-30R outlets, so devices using other connector types will need adapter cables or a downstream PDU. Recharge takes 1.50 hours and typical standby runtime at full load is 3.70 minutes.
Replaces Smaller Single-Phase UPS Units When Loads
Stepping up from a 5 kVA or lower tower UPS is justified when rack density grows, when hard-wired installation is mandated, or when network-based fleet management via EcoStruxure IT becomes necessary. The fixed outlet count and lack of included rail kits mean installers must plan cable routing and procure SRTRK2 or SRTRK3 rails separately.
Highlights
- Pure sine wave protects sensitive equipment
- 10 kVA on-line topology delivers continuous power
- 70 minute standby at full load
- 50 hour recharge restores backup fast
- Network card plus SmartSlot enables remote management
Specifications
No published specifications for this item yet.
Questions about this item
Should I choose the L6-20R or L6-30R outlets for my servers?
The unit provides four L6-20R outlets rated for 20 A and two L6-30R outlets rated for 30 A; match each server's power cord to the corresponding receptacle.
What does the 10 kVA rating mean for my actual load?
It delivers 10 kW of real power with a unity power factor, so you can connect up to 10 000 watts of equipment without derating.
What input voltage does the hard-wire connection accept and what does that limit?
The hard-wire 3-wire input accepts 208 V or 240 V AC, and the UPS will only operate within those nominal voltages.