APC
APC Metered Rack PDU 2G 208V 5.7KW Zero U C13x36 C19x6 5-20x2 AP8861
A metered rack power distribution unit delivering 5.7 kW at 208 V with 44 outlets in a zero-U form factor
- TypeMonitored
- Metered monitoring enables real-time load visibility via Ethernet and serial interfaces
- 7 kW capacity supports dense rack deployments with 208 V three-phase input
- 44 outlets including 36 C13 and 6 C19 plus two NEMA 5-20R cover diverse equipment
- Zero-U vertical design fits 70.5-inch height without consuming rack units
- Remote HTTP SNMP Telnet access allows centralized power management across the data centre
Rack PDU for 208 V three-phase power
This metered rack PDU distributes 208 V three-phase input across 44 outlets in a zero-U form factor. It targets data-centre racks that need branch-level current visibility without consuming rack units. Remote access uses Ethernet, RS-232, HTTP, SNMP and Telnet for integration with existing monitoring tools.
5.7 kVA capacity with 36 C13.
The unit supports a 5.7 kVA load rating and a 20 A maximum input current, derated to 16 A for North American regulatory compliance. It comfortably powers dense server and networking gear but will trip if sustained draw exceeds the 20 A line limit across all phases.
Monitored metering via Ethernet and RS-232
Real-time current readings are exposed through the RJ-45 and RJ-11 management ports using standard protocols. Environments that require outlet-level switching or per-outlet energy logging cannot be served by this model.
Highlights
- Metered monitoring enables real-time load visibility via Ethernet and serial interfaces
- 7 kW capacity supports dense rack deployments with 208 V three-phase input
- 44 outlets including 36 C13 and 6 C19 plus two NEMA 5-20R cover diverse equipment
- Zero-U vertical design fits 70.5-inch height without consuming rack units
- Remote HTTP SNMP Telnet access allows centralized power management across the data centre
Specifications
| Type | Monitored |
|---|
Questions about this item
Will the 36 C13 and 6 C19 outlets on this PDU power my existing servers that use IEC 60320 C13 and C19 plugs?
Yes, the 36 C13 and 6 C19 outlets accept standard IEC 60320 C13 and C19 plugs used by most rackmount servers and network gear.
How can I verify the AP8861 is metering load correctly after installation?
Connect to the Ethernet RJ-45 or RS-232 RJ-11 management port and check the HTTP, SNMP or Telnet interface for real-time current readings per phase.
Does the AP8861 ship with mounting hardware for a zero-U installation, or must I buy brackets separately?
The unit includes toolless mounting buttons for zero-U vertical mounting in compatible racks; no extra brackets are required.