APC
APC AP9570 Basic PDU 208V 30A 4x C19 1U
A 1U rack PDU distributing 208V power from a 30A NEMA L6-30P inlet to four C19 outlets with overload protection
- TypeBasic
- Rack Size1U
- CertificationscUL Listed,CSA,METI Denan,UL 60950,UL Listed
- ROHSYes
- Input Voltage200V,208V,230V
- Input Frequency50/60 Hz
- Delivers 5.0 kW from a single 30 A branch circuit
- Four IEC C19 outlets power high-density rack equipment
- 1U horizontal form factor fits standard rack enclosures
- 8 ft input cord with NEMA L6-30P plug simplifies placement
- Certified to UL 60950, cUL, CSA and METI Denan standards
Rack Power Distribution Unit
The APC AP9570 is a basic 1U horizontal rackmount power distribution unit designed for server rooms and data centres. It accepts a single 208V 30A feed and provides four IEC 320 C19 outlets for rack-mounted equipment. The unit is certified to cUL, CSA, METI Denan and UL 60950 standards.
Installation Notes
The PDU ships with rack-mounting brackets and an installation guide for horizontal 1U mounting. A 10 ft cord with a NEMA L6-30P plug connects to the branch circuit. Ensure the supply is derated to 24A as required by regulatory limits. Overload protection is built in for connected devices.
Input Connector and Rating
The single input uses a NEMA L6-30P connector rated for 200–230V at 50/60 Hz with a maximum current of 30A and a regulatory derated current of 24A. This connector and current rating determine whether the unit matches your facility power infrastructure.
Highlights
- Delivers 5.0 kW from a single 30 A branch circuit
- Four IEC C19 outlets power high-density rack equipment
- 1U horizontal form factor fits standard rack enclosures
- 8 ft input cord with NEMA L6-30P plug simplifies placement
- Certified to UL 60950, cUL, CSA and METI Denan standards
Specifications
| Brand | APC |
|---|---|
| Model | AP9570 |
| Type | Basic |
| Rack Size | 1U |
| Certifications | cUL Listed,CSA,METI Denan,UL 60950,UL Listed |
| ROHS | Yes |
| Input Voltage | 200V,208V,230V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 30A |
| Regulatory Derated Input Current | 24A |
| Input Connector(s) | NEMA L6-30P |
| Cord Length | 10 ft |
| Output Voltage | 208V |
| Output Connector(s) | (4) IEC 320 C19 |
| Overload Protection | Yes |
| Operating Environment | 0 - 45 °C |
| Operating Relative Humidity | 0 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -25 - 65 ºC |
| Storage Relative Humidity | 0 - 95% |
| Storage Elevation | 0 - 15000 m |
| Dimensions | 1.73" x 17.60" x 2.53" (H x W x D) |
| Weight | 6.00 lbs. |
| Shipping weight | 4.08 kg |
| Package size | 464 × 229 × 70 mm |
Questions about this item
How can I verify the PDU is distributing power correctly after installing it in the rack?
After connecting the NEMA L6-30P plug to a 208V 30A source, check that the overload protection has not tripped and that each of the four C19 outlets delivers 208V to the attached equipment.
What ships with the AP9570 and what must I source separately?
The unit includes an installation guide and rack-mounting brackets for 1U horizontal mounting; you must provide the NEMA L6-30P input circuit and IEC C19-to-C20 cords for your devices.
Which capacity should I choose if my rack runs on a 208V single-phase feed?
This model is rated for 208V input at a 24A derated continuous load (5.0 kW) with four C19 outlets, matching a standard 30A branch circuit.