We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP9565 Basic PDU 1U 16A 200-230V 12×C13

SKU CH-9RST-KWNZ5 MPN AP9565

Distributes 200–230 V power to twelve C13 outlets from a single 16 A IEC-320 C20 input in a 1U horizontal rackmount with 8.2 ft cord

  • TypeBasic
  • Rack Size1U
  • CertificationscUL Listed, CE, Queensland Australia, UL 60950, UL Listed, V
  • ROHSYes
  • Package IncludesRack PDU, Installation Guide, Rack Mounting Brackets
  • Input Voltage200V, 208V, 230V
  • Distributes power to twelve C13 outlets from a single 16A source
  • Fits a standard 1U rack space for dense cabinet deployments
  • Supports 200 V to 230 V input across 50 Hz or 60 Hz mains
  • Includes mounting brackets and an 8.2 ft cord for flexible installation
  • Certified to cUL, CE, VDE and UL 60950 for regulated environments

1U 16A Basic PDU with 12 C13 Outlets

The APC AP9565 is a 1U horizontal rackmount power distribution unit designed for 200V to 230V environments. It provides twelve IEC 320 C13 outlets fed from a single IEC-320 C20 input rated at 16A. The unit includes mounting brackets and an installation guide for standard rack integration.

Sustained 3.7 kW Load Distribution

The PDU delivers continuous power distribution up to 3.7 kW across all twelve outlets without metering or switching functions. It operates reliably in temperatures from 0 to 45 degrees Celsius and humidity up to 95 percent non-condensing. Certifications including cUL Listed, CE, VDE and UL 60950 confirm compliance for sustained operation in data centre and network closet environments.

Replaces Unmanaged Strip PDUs in 1U Spaces

This unit upgrades basic power strips by adding certified rackmount brackets, a 2.5 metre input cord and twelve locking-compatible C13 receptacles in a single rack unit. The jump is worth it when you need agency-approved power distribution for up to 16A at 208V or 230V without the cost of metered or switched PDUs. It does not suit installations requiring per-outlet monitoring, remote power cycling or input voltages below 200V.

Highlights

  • Distributes power to twelve C13 outlets from a single 16A source
  • Fits a standard 1U rack space for dense cabinet deployments
  • Supports 200 V to 230 V input across 50 Hz or 60 Hz mains
  • Includes mounting brackets and an 8.2 ft cord for flexible installation
  • Certified to cUL, CE, VDE and UL 60950 for regulated environments

Specifications

BrandAPC
ModelAP9565
TypeBasic
Rack Size1U
CertificationscUL Listed, CE, Queensland Australia, UL 60950, UL Listed, VDE
ROHSYes
Package IncludesRack PDU, Installation Guide, Rack Mounting Brackets
Input Voltage200V, 208V, 230V
Input Frequency50/60 Hz
Maximum Input Current16A
Cord Length8.2 Feet
Output Voltage208V, 230V
Output Connector(s)12 x IEC 320 C13 (Battery Backup)
Operating Environment0 - 45 Degree Celcius
Operating Relative Humidity0 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-25 - 65 Degree Celcius
Storage Relative Humidity0 - 95%
Storage Elevation0 - 15000 m
FeaturesLow Cost Power Distribution
Rack-Mountable
Single input power source
Wide range of input and output connections
Dimensions1.75" x 2.25" x 17.60"
Weight4.50 lbs.
Shipping weight2.50 kg
Package size635 × 356 × 305 mm

Questions about this item

Does the AP9565 generate noticeable heat or noise when distributing 16 A continuously?

The unit is a passive Basic PDU with no fans, so it adds no audible noise; heat output is limited to normal conduction losses at up to 3.7 kW load within the 0 – 45 °C operating range.

What must I already have to connect the AP9565 to my rack equipment?

You need a 200 – 230 V source with an IEC-320 C20 inlet and twelve IEC C13 cables to reach your devices; mounting brackets and an installation guide are included.

Will the AP9565 work alongside older servers that only accept 120 V C13 feeds?

The PDU outputs 208 V or 230 V on every C13 outlet, so 120 V-only gear cannot be powered directly from this unit.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.