We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8959NA3 Switched PDU 200-240V 20A 21 C13 3 C19 0U

SKU CH-9Q0G-1VRZ2 MPN AP8959NA3

Switched PDU distributes 200-240 V power to twenty-one C13 and three C19 outlets with remote on/off control and real-time load monitoring in a 0U vertical form factor

  • TypeSwitched
  • Rack Size0U
  • CertificationscUL Listed,EN 55022 Class A,EN 55024,EN 61000-3-2,EN 61000-3
  • ROHSYes
  • Input Voltage200V,208V,230V
  • Input Frequency50/60 Hz
  • Remote reboot and outlet control via switched outlets
  • 21 C13 and 3 C19 outlets support dense equipment
  • 0U vertical mounting saves rack space
  • 200-240V input with 20A NEMA L6-20P plug
  • Real-time current metering with user-defined alarms

Vertical Switched PDU 0U

The APC AP8959NA3 is a vertical 0U switched power distribution unit designed for rack environments. It accepts 200-240 V single-phase input through a NEMA L6-20P plug and delivers power through twenty-one C13 and three C19 locking outlets. Remote outlet switching enables power cycling and access control for connected equipment.

IT managers needing remote reboot and sequencing

This unit suits administrators who require outlet-level on/off control, power-on sequencing delays and real-time current metering with alarm thresholds. Management is available via web, SNMP, CLI or Telnet and integrates with APC centralised platforms. Sites without 200-240 V single-phase supply, without a NEMA L6-20P feed, or needing fewer than twenty-four outlets should consider other options.

20 A input with 16 A derated limit

The regulatory derated input current is 16 A at 208 V output, which determines the maximum continuous load the PDU can support. Exceeding this limit will trip the upstream breaker regardless of the 20 A plug rating. Verify that the total connected equipment draws no more than 16 A before deployment.

Highlights

  • Remote reboot and outlet control via switched outlets
  • 21 C13 and 3 C19 outlets support dense equipment
  • 0U vertical mounting saves rack space
  • 200-240V input with 20A NEMA L6-20P plug
  • Real-time current metering with user-defined alarms

Specifications

BrandAPC
ModelAP8959NA3
TypeSwitched
Rack Size0U
CertificationscUL Listed,EN 55022 Class A,EN 55024,EN 61000-3-2,EN 61000-3-3,FCC Part 15 Class A,ICES-003,PSE,UL Listed,VCCI Class A,VDE
ROHSYes
Input Voltage200V,208V,230V
Input Frequency50/60 Hz
Maximum Input Current20A
Regulatory Derated Input Current16A
Input Connector(s)NEMA L6-20P
Cord Length9.84 ft.
Output Voltage208V
Output Connector(s)(21) IEC 320 C13
(3) IEC 320 C19
Operating Environment-5 - 45 ºC
Operating Relative Humidity5 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-25 - 65 ºC
Storage Relative Humidity5 - 95%
Storage Elevation0 - 15000 m
FeaturesNetwork Management:
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Remote Individual Outlet Control:
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoi
Dimensions70.5" x 2.2" x 1.82"
Weight12.6 lbs
Shipping weight9.07 kg
Package size2002 × 165 × 114 mm

Questions about this item

What rack space does the 0U vertical PDU require for mounting?

The AP8959NA3 mounts in 0U vertical space, using the full height of a standard rack without consuming horizontal rack units, and includes tool-less mounting brackets for quick installation.

How is the NEMA L6-20P input connected and what derating step is often missed?

Plug the 9.84 ft cord into a 200-240V 20A branch circuit; the regulatory derated input current is 16A, so the PDU must not draw more than 3.3 kW continuous load to stay within code limits.

When should the locking IEC C13 and C19 receptacles be inspected or replaced?

Inspect the 21 C13 and 3 C19 locking receptacles during routine maintenance cycles; replace any that show contact wear, cracked housings, or failure to lock securely to prevent accidental disconnects under load.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.