APC
APC AP8932 Switched PDU 100-120V 30A 24x 5-20R 0U Vertical
A switched 30 A PDU with 24 NEMA 5-20R outlets, vertical 0U mounting and remote outlet control for 100-120 V racks
- TypeSwitched
- Rack Size0U
- Front Panel LEDs0U
- CertificationscUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1,
- ROHSYes
- Input Voltage100V, 120V
- Remote outlet power cycling reboots locked-up gear without a site visit
- 24 NEMA 5-20R outlets serve dense 1U or blade chassis in a single 0U strip
- 30 A derated to 24 A continuous protects branch circuits from overload
- Real-time current metering and user-defined alarms flag trouble before breakers trip
- 8 ft input cord with NEMA L5-30P reaches overhead busway or floor PDU
Switched 30A PDU for rack power control
The APC AP8932 is a switched rack power distribution unit built for IT environments that need remote outlet management. It accepts 100-120V input through a NEMA L5-30P plug and delivers power to twenty-four NEMA 5-20R outlets. The 0U vertical form factor mounts in the rack’s zero-U space without consuming equipment units.
24A derated input current sets usable capacity
The regulatory derated input current is 24A, which limits continuous load on the 30A branch circuit. This figure determines how much equipment can be safely connected without tripping the internal breaker. Exceeding the derated value risks overload even if the plug rating is higher.
Passive cooling within -5 to 45 °C range
The unit operates passively across a -5 to 45 °C temperature window and 5 to 95 % relative humidity. No fans are fitted, so acoustic output is negligible in normal use. Power draw is limited to the connected load plus minimal metering electronics.
Highlights
- Remote outlet power cycling reboots locked-up gear without a site visit
- 24 NEMA 5-20R outlets serve dense 1U or blade chassis in a single 0U strip
- 30 A derated to 24 A continuous protects branch circuits from overload
- Real-time current metering and user-defined alarms flag trouble before breakers trip
- 8 ft input cord with NEMA L5-30P reaches overhead busway or floor PDU
Specifications
| Brand | APC |
|---|---|
| Model | AP8932 |
| Type | Switched |
| Rack Size | 0U |
| Front Panel LEDs | 0U |
| Certifications | cUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1, UL Listed |
| ROHS | Yes |
| Input Voltage | 100V, 120V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 30A |
| Regulatory Derated Input Current | 24A |
| Input Connector(s) | NEMA L5-30P |
| Cord Length | 10 ft |
| Output Voltage | 100V, 120V |
| Output Connector(s) | 24 x NEMA 5-20R |
| Overload Protection | Yes |
| Operating Environment | -5 - 45 ºC |
| Operating Relative Humidity | 5 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -25 - 65 ºC |
| Storage Relative Humidity | 5 - 95% |
| Storage Elevation | 0 - 15000 m |
| Features | APC Rack PDU 2G, Switched, ZeroU, 30A, 100 - 120V, 24 x 5-20R - 24 x NEMA 5-20R - 2.88 kVA - 0U Horizontal Rackmount, Vertical Rackmount, Toolless-mount |
| Weight | 17.27 lbs. |
| Shipping weight | 9.98 kg |
| Package size | 2004 × 165 × 108 mm |
Questions about this item
What does the 30 A input rating mean for the actual load I can run?
The regulatory derated current is 24 A, so continuous draw should stay at or below that figure on a 100–120 V supply.
What does the NEMA L5-30P input plug limit in practice?
It caps the PDU to 30 A single-phase service at 100–120 V and requires a matching L5-30R receptacle on the branch circuit.
How does the 0U vertical form factor mount in a rack?
The unit installs vertically in the 0U space alongside the equipment rails, using the supplied toolless mounting brackets.