We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8932 Switched PDU 100-120V 30A 24x 5-20R 0U Vertical

SKU CH-GNEC-774BJ MPN AP8932

A switched 30 A PDU with 24 NEMA 5-20R outlets, vertical 0U mounting and remote outlet control for 100-120 V racks

  • TypeSwitched
  • Rack Size0U
  • Front Panel LEDs0U
  • CertificationscUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1,
  • ROHSYes
  • Input Voltage100V, 120V
  • Remote outlet power cycling reboots locked-up gear without a site visit
  • 24 NEMA 5-20R outlets serve dense 1U or blade chassis in a single 0U strip
  • 30 A derated to 24 A continuous protects branch circuits from overload
  • Real-time current metering and user-defined alarms flag trouble before breakers trip
  • 8 ft input cord with NEMA L5-30P reaches overhead busway or floor PDU

Switched 30A PDU for rack power control

The APC AP8932 is a switched rack power distribution unit built for IT environments that need remote outlet management. It accepts 100-120V input through a NEMA L5-30P plug and delivers power to twenty-four NEMA 5-20R outlets. The 0U vertical form factor mounts in the rack’s zero-U space without consuming equipment units.

24A derated input current sets usable capacity

The regulatory derated input current is 24A, which limits continuous load on the 30A branch circuit. This figure determines how much equipment can be safely connected without tripping the internal breaker. Exceeding the derated value risks overload even if the plug rating is higher.

Passive cooling within -5 to 45 °C range

The unit operates passively across a -5 to 45 °C temperature window and 5 to 95 % relative humidity. No fans are fitted, so acoustic output is negligible in normal use. Power draw is limited to the connected load plus minimal metering electronics.

Highlights

  • Remote outlet power cycling reboots locked-up gear without a site visit
  • 24 NEMA 5-20R outlets serve dense 1U or blade chassis in a single 0U strip
  • 30 A derated to 24 A continuous protects branch circuits from overload
  • Real-time current metering and user-defined alarms flag trouble before breakers trip
  • 8 ft input cord with NEMA L5-30P reaches overhead busway or floor PDU

Specifications

BrandAPC
ModelAP8932
TypeSwitched
Rack Size0U
Front Panel LEDs0U
CertificationscUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1, UL Listed
ROHSYes
Input Voltage100V, 120V
Input Frequency50/60 Hz
Maximum Input Current30A
Regulatory Derated Input Current24A
Input Connector(s)NEMA L5-30P
Cord Length10 ft
Output Voltage100V, 120V
Output Connector(s)24 x NEMA 5-20R
Overload ProtectionYes
Operating Environment-5 - 45 ºC
Operating Relative Humidity5 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-25 - 65 ºC
Storage Relative Humidity5 - 95%
Storage Elevation0 - 15000 m
FeaturesAPC Rack PDU 2G, Switched, ZeroU, 30A, 100 - 120V, 24 x 5-20R - 24 x NEMA 5-20R - 2.88 kVA - 0U Horizontal Rackmount, Vertical Rackmount, Toolless-mount
Weight17.27 lbs.
Shipping weight9.98 kg
Package size2004 × 165 × 108 mm

Questions about this item

What does the 30 A input rating mean for the actual load I can run?

The regulatory derated current is 24 A, so continuous draw should stay at or below that figure on a 100–120 V supply.

What does the NEMA L5-30P input plug limit in practice?

It caps the PDU to 30 A single-phase service at 100–120 V and requires a matching L5-30R receptacle on the branch circuit.

How does the 0U vertical form factor mount in a rack?

The unit installs vertically in the 0U space alongside the equipment rails, using the supplied toolless mounting brackets.