We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8886 Metered PDU 0U 400V 32A 30×C13 12×C19

SKU CH-C55K-RWD7F MPN AP8886

A 0U metered rack PDU delivering 230V from a 400V three-phase 32A feed, with 30 C13 and 12 C19 outlets and a local current display for overload prevention

  • TypeMetered
  • Rack Size0U
  • CertificationsEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC
  • ROHSYes
  • Input Voltage400V 3PH
  • Input Frequency50/60 Hz
  • Digital display shows real-time aggregate current draw to prevent overloads
  • LED load indicator warns of overload and threshold breaches at a glance
  • 30 IEC C13 and 12 IEC C19 outlets support dense 230 V equipment
  • 0U vertical form factor fits 72 in rack height without consuming U-space
  • 400 V three-phase 32 A input delivers up to 14.4 kW per branch whip

Metered 0U PDU for 400V three-phase racks

This metered power distribution unit mounts in a 0U form factor and accepts 400V three-phase input at up to 32A through an IEC 309 3P+N+E connector. It delivers 230V output to thirty C13 and twelve C19 locking receptacles. A local digital display shows aggregate current draw so installers can avoid overloads in high-density environments.

Interface limits of the IEC 309 32A input

The IEC 309 32A 3P+N+E plug restricts the unit to supplies that provide 400V three-phase power at 50 or 60 Hz with a matching socket. Maximum input current is capped at 32A, so total connected load must stay within that limit. Operating temperature range is 0 to 55 °C with humidity from 5 to 95 % non-condensing, and altitude up to 3000 m.

Forty-two locking outlets decide fit

The combination of thirty C13 and twelve C19 receptacles determines whether the PDU matches the cable ends on your servers and network gear. Both outlet types are IEC 320 locking style to prevent accidental disconnection. If your equipment uses different plug types or requires a different outlet count, this unit will not suit the rack.

Highlights

  • Digital display shows real-time aggregate current draw to prevent overloads
  • LED load indicator warns of overload and threshold breaches at a glance
  • 30 IEC C13 and 12 IEC C19 outlets support dense 230 V equipment
  • 0U vertical form factor fits 72 in rack height without consuming U-space
  • 400 V three-phase 32 A input delivers up to 14.4 kW per branch whip

Specifications

BrandAPC
ModelAP8886
TypeMetered
Rack Size0U
CertificationsEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, VCCI Class A, VDE
ROHSYes
Input Voltage400V 3PH
Input Frequency50/60 Hz
Maximum Input Current32A
Input Connector(s)IEC 309 32A 3P+N+E
Output Voltage230V
Output Connector(s)(30) IEC 320 C13
(12) IEC 320 C19
Overload ProtectionYes
Operating Environment0 - 55 °C
Operating Relative Humidity5 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-25 - 65 ºC
Storage Relative Humidity5 - 95%
Storage Elevation0 - 15000 m
Dimensions72.00" x 2.20" x 2.00" (H x W x D)
Weight19.18 lbs.
Shipping weight11.52 kg
Package size2050 × 170 × 112 mm

Questions about this item

Should I choose a PDU with more C13 or more C19 outlets for my rack?

This unit provides 30 C13 outlets for standard server cords and 12 C19 outlets for high-power equipment, letting you match the mix to your devices.

What does the 32A rating mean for actual power delivery at 230V?

The 32A three-phase input at 400V supports up to 22kW total, with the metered display showing real-time aggregate current so you stay below the 32A limit per phase.

How does the IEC 309 32A 3P+N+E input connector limit installation options?

It requires a matching 32A three-phase supply with neutral and earth, common in European data centres, and fixes the maximum input current at 32A per phase.