We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8868 Metered PDU 10.0kW 208V 3PH 35A CS8365 (36) C13 (6) C19

SKU CH-SR51-E3DPA

A metered power distribution unit delivering 10.0 kW at 208 V three-phase with 36 C13 and 6 C19 outlets, 35 A input via CS8365 plug, and real-time load monitoring

  • TypeMetered
  • Rack Size0U
  • CertificationscUL Listed,EN 55022 Class A,EN 55024,EN 61000-3-2,EN 61000-3
  • ROHSYes
  • Input Voltage208V 3PH
  • Input Frequency50/60 Hz
  • Metered monitoring enables energy optimisation and circuit protection
  • 0 kW output at 208 V three-phase powers dense rack loads
  • 35 A maximum input current with CS8365 connector fits 35 A branch circuits
  • 36 C13 plus 6 C19 outlets support mixed-density equipment
  • ZeroU vertical form factor preserves horizontal rack space

10 kW 3-phase metered PDU

The APC AP8868 is a ZeroU metered rack power distribution unit rated for 10.0 kW at 208 V three-phase with a 35 A CS8365 input. It suits data-centre operators who need per-outlet energy visibility and overload alerts on high-density racks.

36 C13 and 6 C19 outlets

The unit provides thirty-six IEC 320 C13 and six IEC 320 C19 receptacles, allowing mixed server and networking gear to connect without adapter cables. Active metering with user-defined alarm thresholds delivers real-time local and remote warnings before a circuit approaches its 35 A limit.

208 V three-phase supply and 6 ft cord

Verify that the facility delivers 208 V three-phase power at 50 or 60 Hz and that the CS8365 plug matches the upstream receptacle. The 1.83 m cord length restricts placement to within that distance of the source, and the operating envelope is 0 to 55 °C at up to 95 % humidity.

Highlights

  • Metered monitoring enables energy optimisation and circuit protection
  • 0 kW output at 208 V three-phase powers dense rack loads
  • 35 A maximum input current with CS8365 connector fits 35 A branch circuits
  • 36 C13 plus 6 C19 outlets support mixed-density equipment
  • ZeroU vertical form factor preserves horizontal rack space

Specifications

BrandAPC
ModelAP8868
TypeMetered
Rack Size0U
CertificationscUL Listed,EN 55022 Class A,EN 55024,EN 61000-3-2,EN 61000-3-3,FCC Part 15 Class A,ICES-003,UL Listed,VCCI Class A
ROHSYes
Input Voltage208V 3PH
Input Frequency50/60 Hz
Maximum Input Current35A
Input Connector(s)CS8365
Cord Length6 ft
Output Voltage208V
Output Watts (VA)10.0kW
Output Connector(s)(36) IEC 320 C13
(6) IEC 320 C19
Overload ProtectionYes
Operating Environment0 - 55 degree C
Operating Relative Humidity5 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-25 - 65 ºC
Storage Relative Humidity5 - 95%
Storage Elevation0 - 15000 m
FeaturesAPC Rack PDU 2G, Metered, ZeroU, 10.0kW, 208V, (36) C13 & (6) C19 - 36 x IEC 60320 C13, 6 x IEC 60320 C19 - 10 kVARack-mountable
Dimensions72.01" x 2.2" x 2.01"
Weight18.78 lbs.

Questions about this item

When will the IEC 320 C13 and C19 outlets need replacement under normal rack use?

The outlets are rated for the unit's 35 A maximum current draw and 10.0 kW capacity; replacement is only required if physical damage or overheating occurs during operation within the 0–55 °C range.

What is the first limit reached when running the PDU continuously at full 10.0 kW load?

The 35 A input current limit on the CS8365 connector is reached before any thermal or voltage threshold at 208 V three-phase.

How much heat does the AP8868 add to the rack when metering 10.0 kW all day?

As a passive distribution unit it adds negligible heat; the rack environment must simply stay within the 0–55 °C operating temperature and 5–95 % humidity limits.