APC AP8866US Metered 0U PDU 17.3kW 208V 3‑Phase 60A 6 C13 12 C19
A metered 0U power distribution unit delivering 17.3 kW at 208 V three-phase with six C13 and twelve C19 outlets
- TypePDUs & Line Conditioners
- Metered input monitoring prevents overloads on 3‑phase 208V supply
- 18 outlets (6 C13 + 12 C19) fit dense rack equipment
- Zero‑U vertical mount saves horizontal rack space
- 3 kW capacity at 60 A supports high‑power loads
- cUL and UL listed for North American safety compliance
Zero-U rack PDU for three-phase power
This APC NetShelter unit mounts vertically in a standard rack and delivers metered three-phase distribution at 208 V. It is built for data-centre rows and high-density server cabinets that need branch-level current visibility without consuming horizontal rack space.
17.3 kW capacity with 60 A input rating
The single specification that decides fit is the 17.3 kW / 60 A three-phase rating at 208 V; the unit will not support loads that exceed this envelope. Buyers whose equipment requires a different voltage, phase count or higher amperage must select another model.
Eighteen locking outlets and bundled mounting kit
Six C13 and twelve C19 receptacles accept both standard and high-current server cords, while the included 0U brackets, serial configuration cable and printed guides enable immediate rack installation and local metering setup.
Highlights
- Metered input monitoring prevents overloads on 3‑phase 208V supply
- 18 outlets (6 C13 + 12 C19) fit dense rack equipment
- Zero‑U vertical mount saves horizontal rack space
- 3 kW capacity at 60 A supports high‑power loads
- cUL and UL listed for North American safety compliance
Specifications
| Brand | APC |
|---|---|
| Model | AP8866US |
| Part Number | AP8866US |
| Type | PDUs & Line Conditioners |
| Shipping weight | 13.61 kg |
| Package size | 2134 × 216 × 114 mm |
Questions about this item
What does the 17.3 kW rating mean once the unit is installed in a rack?
It indicates the maximum continuous three-phase load the PDU can distribute at 208 V without tripping its 60 A input breaker.
How does the three-phase 208 V input limit what can be plugged into the C13 and C19 outlets?
Each outlet group draws from one phase, so the 60 A per phase cap applies to the combined load on the outlets fed by that phase.
What hardware is included to mount this 0U PDU in a standard rack?
The package supplies rack-mounting brackets that attach to the PDU chassis for vertical 0U installation.