We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
APC
A metered three-phase PDU delivering 208 V power through twelve C19 and six C13 outlets in a 0U vertical form factor
The APC AP8866 is a 0U vertical power distribution unit built for 208V three-phase environments. It delivers 17.3 kVA through eighteen locking outlets fed by a six-foot IEC 309 60A 3P+PE input cord. Real-time metering lets operators track aggregate load on each phase.
Suits data-centre cabinets that need twelve C19 and six C13 receptacles in a single vertical strip. The 48 A derated limit per phase means sites planning sustained draws above that level must provision additional circuits. Facilities running single-phase feeds or lower amperage service cannot use this unit.
The 0U form factor slides into standard cabinet side channels without consuming rack units. Installers must verify that the IEC 309 plug matches the upstream receptacle and that branch breakers are rated for 60 A per phase. Overload protection trips locally, so a tripped breaker requires physical access to reset.
| Brand | APC |
|---|---|
| Model | AP8866 |
| Type | Metered |
| Rack Size | 0U |
| Style | Vertical |
| Input Voltage | 208V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | Maximum Line Current per phase: 48A Maximum Input Current per phase: 60A |
| Regulatory Derated Input Current | 48A |
| Input Connector(s) | IEC 309 60A 3P+PE |
| Cord Length | 6 ft |
| Output Voltage | 208V |
| Output Connector(s) | (6) IEC 320 C13 (12) IEC 320 C19 |
| Overload Protection | Yes |
| Operating Relative Humidity | 5 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -25 - 65 ºC |
| Storage Relative Humidity | 5 - 95% |
| Storage Elevation | 0 - 15000 m |
| Features | Load Capacity 17.3 kVA |
| Dimensions | 72.01" x 2.2" x 2.01" |
| Weight | 20.94 lbs. |
| Shipping weight | 13.52 kg |
| Package size | 2149 × 221 × 112 mm |
The unit requires a three-phase 208 V source with an IEC 309 60 A 3P+PE inlet; the 5.9 ft cord plugs directly into that receptacle.
Yes, each outlet delivers 208 V single-phase power; the PDU distributes the three-phase input across all 18 receptacles so older gear works without modification.
Apply a known load and verify the front-panel meter shows the expected kVA reading up to the 17.3 kVA capacity while staying within the 48 A derated per-phase limit.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?