We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8861 Metered PDU 208V 3Ph 20A 36×C13 6×C19 2×5-20R 0U

SKU CH-W9ST-SK17B MPN AP8861

Metered 208 V three-phase PDU with 36 C13, 6 C19 and 2 NEMA 5-20R outlets in a 0U vertical form factor

  • TypeMetered
  • Rack Size0U
  • StyleRack
  • CertificationsCSA C22.2 No. 60950,UL 60950-1
  • ROHSYes
  • Input Voltage208V
  • Metered input monitoring tracks 5.7 kW three-phase load
  • 44 outlets include 36 C13, 6 C19 and 2 NEMA 5-20R
  • 0U vertical mounting fits rack without consuming U space
  • Certified to UL 60950-1 and CSA C22.2 No. 60950
  • 6 ft cord with NEMA L21-20P plug reaches 208V source

Three-phase metered PDU for dense racks

The APC AP8861 is a 0U vertical rack-mount power distribution unit that delivers metered 208V three-phase power at a regulatory derated 16A input. It accepts a NEMA L21-20P plug on a 5.9-foot cord and provides forty-four outlets in three types. The unit operates from -5 to 45 °C at up to 3000 m elevation.

Suited for server rows needing outlet-level

This PDU fits administrators who want real-time current readouts on a three-phase feed and a mix of C13, C19 and 5-20R receptacles in a single 0U chassis. Buyers who need switched outlets, per-outlet metering or a single-phase input should look at other models.

Verify three-phase 208V service

Confirm the facility provides a 208V three-phase circuit with a NEMA L21-20 receptacle and that the 5.9-foot cord reaches from that receptacle to the rack mounting location. Ensure the 16A derated limit matches the planned load and that the operating temperature range suits the room environment.

Highlights

  • Metered input monitoring tracks 5.7 kW three-phase load
  • 44 outlets include 36 C13, 6 C19 and 2 NEMA 5-20R
  • 0U vertical mounting fits rack without consuming U space
  • Certified to UL 60950-1 and CSA C22.2 No. 60950
  • 6 ft cord with NEMA L21-20P plug reaches 208V source

Specifications

BrandAPC
ModelAP8861
TypeMetered
Rack Size0U
StyleRack
CertificationsCSA C22.2 No. 60950,UL 60950-1
ROHSYes
Input Voltage208V
Input Frequency50/60 Hz
Regulatory Derated Input Current16A
Input Connector(s)NEMA L21-20P
Cord Length6 ft
Output Voltage208V
Output Connector(s)(36) IEC 320 C13
(6) IEC 320 C19
(2) NEMA 5-20R
Operating Environment-5 - 45 ºC
Operating Relative Humidity5 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-25 - 65 ºC
Storage Relative Humidity5 - 95%
Storage Elevation0 - 15000 m
FeaturesAPC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers.
Dimensions70.51" x 2.2" x 1.73"
Weight13.98 lbs
Shipping weight12.25 kg
Package size2000 × 165 × 102 mm