We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8858NA3 Metered PDU 208V 20A 18×C13 2×C19 0U

SKU CH-H04P-5N9P4 MPN AP8858NA3

A metered 208 V vertical rack PDU with eighteen C13 and two C19 outlets, NEMA L6-20P input and 9.8 ft cord

  • TypeMetered
  • CertificationsCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE
  • Input Voltage200V,208V,230V
  • Input Frequency50/60 Hz
  • Maximum Input Current20A
  • Regulatory Derated Input Current16A
  • Metered monitoring tracks 208 V 20 A load in real time
  • Eighteen C13 plus two C19 outlets power dense server racks
  • 0U vertical design fits 35.5 in height without using rack units
  • 10 ft NEMA L6-20P cord reaches distant PDUs or wall outlets
  • CSA IEC METI UL VDE certifications meet global safety standards

Metered PDU for 208 V racks

The APC AP8858NA3 is a metered power distribution unit built for 200 V to 230 V environments. It delivers 208 V output through eighteen IEC 320 C13 and two IEC 320 C19 outlets. A NEMA L6-20P plug connects to a 10 ft cord. The 0U vertical form factor mounts inside standard racks without consuming horizontal rack units.

Passive cooling with local metering

The unit operates without internal fans, relying on ambient airflow within the rack enclosure. This design produces no audible noise and adds no active power draw beyond the connected loads. A built-in meter displays real-time current up to the 16 A derated limit, helping operators avoid overloads on the 20 A branch circuit. Certifications include UL 60950-1, CSA C22.2 No. 60950, IEC 60950, METI Denan and VDE.

Vertical mounting frees horizontal space

The 35.5 in tall by 2.2 in wide by 1.7 in deep chassis fits alongside equipment in 0U mounting channels. This placement preserves all horizontal rack units for servers, switches or storage arrays. The 6.46 lb weight is supported by the rack structure itself. Management protocols include SNMP and Telnet for remote monitoring. Builds requiring front-facing outlets or horizontal PDU trays will need a different form factor.

Highlights

  • Metered monitoring tracks 208 V 20 A load in real time
  • Eighteen C13 plus two C19 outlets power dense server racks
  • 0U vertical design fits 35.5 in height without using rack units
  • 10 ft NEMA L6-20P cord reaches distant PDUs or wall outlets
  • CSA IEC METI UL VDE certifications meet global safety standards

Specifications

BrandAPC
ModelAP8858NA3
TypeMetered
CertificationsCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE
Input Voltage200V,208V,230V
Input Frequency50/60 Hz
Maximum Input Current20A
Regulatory Derated Input Current16A
Input Connector(s)NEMA L6-20P
Cord Length10 ft
Output Voltage208V
Output Connector(s)(18) IEC 320 C13
(2) IEC 320 C19
FeaturesAPC Metered Rack AP8858NA3 20-Outlets PDU - Rack-mountable
Dimensions4.000
Weight12
Shipping weight5.44 kg
Package size1124 × 162 × 107 mm

Questions about this item

How do I mount the 0U vertical PDU in a rack, and which step is often missed?

Mount the unit vertically using the 0U brackets so the 35.5-inch height fits alongside rack rails; the step often missed is securing both top and bottom brackets to prevent the 6.46 lb unit from sagging.

What maintenance will the metered PDU need over time?

No user-serviceable parts are inside; periodically verify the digital meter reads within the 16 A derated limit and inspect the 9.8 ft NEMA L6-20P cord for damage.

At what load does the 208 V PDU hit its regulatory limit first?

The regulatory derated input current of 16 A is reached before the 20 A breaker, so sustained draw above 3.3 kW will trip the derating threshold.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.