APC
APC AP7920B Switched PDU 1U 12A 208V 10A 230V 8×C13
Switched 1U rack PDU with eight C13 outlets, remote on/off control per outlet, 12 A at 208 V or 10 A at 230 V, and a 6.5 ft C14 input cord
- TypeSwitched
- Rack Size1U
- CertificationscUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-
- ROHSYes
- ConnectivityIEC-320 C14
- Input Voltage200V, 208V, 230V
- Switched outlets enable remote power cycling per device
- 1U form factor fits standard rack enclosures
- Digital display shows real-time aggregate current draw
- Supports 208V and 230V input voltages
- Eight IEC C13 outlets distribute power to rack equipment
Switched Rack PDU 1U 8×C13
The APC AP7920B is a switched rack power distribution unit that fits a single 1U space. It provides eight IEC 320 C13 outlets with independent on-off control for each connected device. The unit accepts 200-230V input through a front-mounted C14 inlet with a 6.5-foot cord. A digital display shows aggregate current draw in real time.
Suited for remote outlet switching.
Network administrators can reboot individual servers or cycle power to locked-up gear via Web, Telnet, SNMP, SSH or StruxureWare Data Center Expert without visiting the rack. The eight-outlet count limits use in densely populated cabinets that need more than eight C13 connections. The 15A maximum input current and 12A regulatory derated rating restrict total attached load accordingly.
Input-current limit 12A derated
The regulatory derated input current of 12A at 208V or 10A at 230V is the single figure that determines how much equipment the PDU can safely support. Aggregate current shown on the display must remain at or below this limit to avoid tripping the upstream breaker. Operating temperature range is 0-45°C at up to 3000m elevation.
Highlights
- Switched outlets enable remote power cycling per device
- 1U form factor fits standard rack enclosures
- Digital display shows real-time aggregate current draw
- Supports 208V and 230V input voltages
- Eight IEC C13 outlets distribute power to rack equipment
Specifications
| Brand | APC |
|---|---|
| Series | Rack PDU |
| Model | AP7920B |
| Type | Switched |
| Rack Size | 1U |
| Certifications | cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, UL 60950, UL Listed, VDE |
| ROHS | Yes |
| Connectivity | IEC-320 C14 |
| Input Voltage | 200V, 208V, 230V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 15A |
| Regulatory Derated Input Current | 12A |
| Cord Length | 6.5 Feet |
| Output Voltage | 208V, 230V |
| Output Connector(s) | 8 x IEC 320 C13 (Battery Backup) |
| Operating Environment | 0 - 45 degree Celcius |
| Operating Relative Humidity | 0 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -25 - 65 degree Celcius |
| Storage Relative Humidity | 0 - 95% |
| Storage Elevation | 0 - 15000 m |
| Features | Power Delays: Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. Remote Individual Outlet Control: Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Remo |
| Dimensions | 1.73" x 17.50" x 4.25" |
| Weight | 5.00 lbs. |
| Shipping weight | 4.08 kg |
| Package size | 578 × 381 × 114 mm |
Questions about this item
How can I confirm the AP7920B is operating correctly after installation?
The front digital display shows the aggregate current draw in amperes; verify it reads within the 12 A derated limit at 208 V or 10 A at 230 V and that no alarm icons appear.
What ships with the AP7920B and what must I source separately?
The unit includes an attached 6.5 ft (2.4 m) input cord ending in a C14 plug; you must supply eight IEC C13-to-C14 cords for the outlets and a compatible upstream PDU or UPS with a C13 receptacle.
The specs list 12 A at 208 V and 10 A at 230 V — which rating should I plan for?
Plan for the 12 A derated limit when the rack supply is 200–208 V and the 10 A limit when it is 230 V; the PDU auto-ranges across 200 V, 208 V and 230 V inputs.