We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP7564 Basic 0U Rack PDU 5.7kW 208V 20A 36xC13 6xC19

SKU CH-JMEV-GGB2Y MPN AP7564

Distributes 208 V three-phase power to 36 C13 and 6 C19 outlets from a 20 A NEMA L21-20P input in a 0U vertical form factor

  • TypeBasic
  • Rack Size0U
  • CertificationscUL Listed,CSA C22.2 No. 60950-1-03,UL 60950-1,UL Listed
  • ROHSYes
  • Input Voltage208V 3PH
  • Input Frequency50/60 Hz
  • 7 kW capacity powers dense rack equipment
  • 36 C13 and 6 C19 outlets connect many servers
  • 0U vertical design saves rack space
  • cUL and UL 60950-1 listed for safety compliance
  • 3 ft cord with NEMA L21-20P plug for 208 V three-phase input

Zero-U Rack PDU for 208V Three-Phase Power

The APC AP7564 is a basic zero-U rack power distribution unit built for 208 V three-phase input at up to 20 A. It mounts vertically in a server cabinet without consuming horizontal rack space. Thirty-six IEC C13 outlets and six IEC C19 outlets feed rack-mounted servers and network gear from a single three-foot cord terminated with a NEMA L21-20P plug.

5.7 kW Capacity at 16 A Derated Input

The unit delivers a maximum of 5.7 kW output while the regulatory derated input current is limited to 16 A. This single figure determines whether the PDU can support your connected load without tripping the upstream breaker. Exceeding the derated value risks nuisance tripping even though the plug and cord are rated for 20 A.

cUL and CSA 60950-1 Certification for Data-Centre

The PDU carries cUL Listed and CSA C22.2 No. 60950-1-03 certifications plus UL 60950-1 listing, satisfying common data-centre safety requirements. It also meets RoHS directives. No monitoring, switching or metering functions are included; the unit provides basic power distribution only.

Highlights

  • 7 kW capacity powers dense rack equipment
  • 36 C13 and 6 C19 outlets connect many servers
  • 0U vertical design saves rack space
  • cUL and UL 60950-1 listed for safety compliance
  • 3 ft cord with NEMA L21-20P plug for 208 V three-phase input

Specifications

BrandAPC
ModelAP7564
TypeBasic
Rack Size0U
CertificationscUL Listed,CSA C22.2 No. 60950-1-03,UL 60950-1,UL Listed
ROHSYes
Input Voltage208V 3PH
Input Frequency50/60 Hz
Maximum Input Current20A
Regulatory Derated Input Current16A
Input Connector(s)NEMA L21-20P
Cord Length3 ft
Output Voltage208V
Output Connector(s)(36) IEC 320 C13, (6) IEC 320 C19
Operating Environment-5 - 45 ºC
Operating Relative Humidity5 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-25 - 65 ºC
Storage Relative Humidity5 - 95%
Storage Elevation0 - 15000 m
Dimensions70" x 2.2" x 1.73"
Weight12.02 lbs
Shipping weight9.07 kg
Package size2134 × 152 × 127 mm

Questions about this item

What does the 5.7 kW rating mean for equipment I connect?

The 5.7 kW rating is the maximum continuous power the unit can distribute at 208 V three-phase, limited by the 20 A input breaker and the 16 A regulatory derating.

What does the NEMA L21-20P input connector cap in practice?

The NEMA L21-20P plug mates with a 208 V three-phase 20 A receptacle; the built-in breaker and the 16 A derated limit cap total draw at 5.7 kW.

What physical space does the 0U form factor need to mount?

The 0U chassis mounts vertically in the zero-U cavity at the side or rear of a standard 19-inch rack, using the included toolless buttons or brackets.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.