Anvil
Anvil 500340146 Insulation Protection Shield 6 in 18 in length
Pre-galvanised steel shield protects foam or fibreglass insulation on 6–8 in pipes, 18 in long, rated −32 °F to 150 °F
- Pre-galvanized finish resists corrosion
- Steel construction withstands 150 °F maximum operating temperature
- Rated down to -32 °F minimum operating temperature
- Fits 6 in to 8 in pipe with 10.6 in insulation outside diameter
- Meets ANSI/MSS SP-69 and Federal Specification A-A-1192A Type 40 standards
Anvil 18 in Protection Shield
Anvil 500340146 is a pre-galvanised steel shield that fits over foam or fibreglass insulation on 6 in to 8 in pipe. It mounts on a clevis hanger and spans 18 in overall length. The shield meets ANSI/MSS SP-69, Federal Specification A-A-1192A Type 40, MSS SP-58 Type 40 and WW-H-171-E Type 41. It is supplied new and ready for installation.
Suits insulated pipe runs
This shield suits installers protecting 10.6 in outside-diameter insulation with 1 in to 2 in thickness on 6 in to 8 in pipe. It operates from -32 Degrees F to 150 Degrees F. It does not suit uninsulated pipe, smaller insulation diameters, or thicknesses outside the stated range. Builders needing other lengths or mount types must select a different shield.
18 in overall length decides fit
The single specification that decides fit is the 18 in overall length combined with the 10.6 in insulation outside diameter and 1 in to 2 in thickness range. Match these three figures to the pipe run before ordering.
Highlights
- Pre-galvanized finish resists corrosion
- Steel construction withstands 150 °F maximum operating temperature
- Rated down to -32 °F minimum operating temperature
- Fits 6 in to 8 in pipe with 10.6 in insulation outside diameter
- Meets ANSI/MSS SP-69 and Federal Specification A-A-1192A Type 40 standards
Specifications
| Brand | ANVIL |
|---|
Questions about this item
Should I pick the 18 in length or another size for my 6 in pipe?
This shield is made in an 18 in overall length and fits pipe sizes 6 in to 8 in with insulation outside diameter 10.6 in and insulation thickness 1 in to 2 in.
What does the 150 °F maximum operating temperature mean once the shield is installed on my pipe?
The steel shield can withstand continuous service up to 150 °F and down to -32 °F, so it will protect foam or fiberglass insulation through normal heating-system temperature swings.
Which standard caps the design — ANSI/MSS SP-69 Type 40 or another spec?
It meets ANSI/MSS SP-69, Federal Specification A-A-1192A, MSS SP-58 and WW-H-171-E, all rated Type 40 or Type 41 for clevis-hanger-mounted insulation protection shields.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.