Zoro Select
Zoro Select 1-1/2 in Schedule 40 galvanized steel pipe nipple 5 in overall length
Galvanised steel pipe nipple, 1-1/2 in Schedule 40, 5 in overall length, rated 300 psi at 150 °F for air, gas and potable water
- ColorTransparent
- TypePipes, Valves & Fittings
- Corrosion-resistant galvanised finish protects pipe integrity
- Schedule 40 rating handles 300 psi at 150 °F
- Electric resistance weld ensures joint strength
- Suitable for air, gas and potable water systems
- 5 inch overall length fits standard connections
1-1/2 in Schedule 40 Galvanized Steel Pipe Nipple
This 5-inch nipple connects Schedule 40 piping systems using 1-1/2 inch male NPT threads on both ends. It is manufactured from welded steel with a galvanized coating for corrosion resistance in air, gas and potable water lines.
Suitable for Standard Pressure Plumbing
Installers working within a 300 psi rating at 150 °F or 150 psi steam at 350 °F will find this fitting appropriate. It is not intended for systems that exceed these pressure and temperature limits or for applications requiring a different schedule or material.
5-Inch Length with 300 psi Rating
The 5-inch overall length provides a fixed spacing between threaded connections in compatible networks. Headroom ends at the stated maximum operating pressure of 300 psi at 150 °F, beyond which a higher-rated component must be selected.
Highlights
- Corrosion-resistant galvanised finish protects pipe integrity
- Schedule 40 rating handles 300 psi at 150 °F
- Electric resistance weld ensures joint strength
- Suitable for air, gas and potable water systems
- 5 inch overall length fits standard connections
Specifications
| Brand | ZORO SELECT |
|---|---|
| Color | Transparent |
| Type | Pipes, Valves & Fittings |
Questions about this item
What size female NPT fitting do I need to connect this 1-1/2 in Schedule 40 galvanized steel nipple?
You need a 1-1/2 in female NPT fitting to match the male threads on this 5 in nipple.
Will this Schedule 40 nipple handle the same 300 psi pressure rating as my existing Schedule 40 galvanized fittings at 150 °F?
Yes, it is rated for 300 psi at 150 °F and 150 psi steam at 350 °F, matching standard Schedule 40 limits.
How can I confirm the nipple meets the Schedule 40 wall thickness after I install it?
Measure the outside diameter; it should read 1 57/64 in, confirming the correct Schedule 40 dimensions.