Zoeller
Zoeller D293 1 HP 2" 230V Auto Submersible Sewage Pump Trap
1 HP submersible sewage pump moves 122.0 gpm at 15 ft head with vertical float switch and 2 in solids handling
- TypeDrain Components
- Handles 2-inch solids for reliable waste removal
- 1 HP motor delivers 122.0 gpm at 15 ft head
- Hermetically sealed oil-filled motor resists moisture ingress
- Vertical float switch activates at 14 3/4 in on point
- Cast iron construction withstands harsh sewage environments
1 HP 230 V Sewage Pump
The Zoeller D293 is a 1 HP submersible sewage pump built for 230 V single-phase supply. Its cast-iron body and impeller handle solids up to 2 in diameter. A hermetically-sealed, oil-filled motor and carbon-ceramic shaft seal protect internal components. The integral vertical float switch turns the pump on at 14 3/4 in and off at 5 in liquid level.
Residential and Light-Commercial Waste
This pump suits homes or small businesses that need to lift sewage from a basin to a gravity sewer or septic system. The 2 in discharge and 24 in minimum sump diameter match standard residential pits. Installations requiring higher flow at greater head, three-phase power, or a smaller basin should evaluate other models.
Vertical Float Switch Levels
The integral vertical float switch provides fixed actuation points: on at 14 3/4 in and off at 5 in. These levels determine the minimum basin depth and the pumping cycle volume. Buyers must verify that the pit depth and required cycle match these exact switch settings.
Highlights
- Handles 2-inch solids for reliable waste removal
- 1 HP motor delivers 122.0 gpm at 15 ft head
- Hermetically sealed oil-filled motor resists moisture ingress
- Vertical float switch activates at 14 3/4 in on point
- Cast iron construction withstands harsh sewage environments
Specifications
| Type | Drain Components |
|---|---|
| Brand | Zoeller |
| Model | D293 |
Questions about this item
How do I set the vertical float switch so the pump turns on at 14 3/4 in and off at 5 in without the tether snagging?
Mount the pump vertically in a pit at least 24 in wide, route the integral float cord clear of the discharge pipe, and verify the on point at 14 3/4 in and off point at 5 in before backfilling.
Which wear items on the carbon-ceramic shaft seal and cast-iron impeller should I plan to replace after extended service?
The carbon-ceramic shaft seal and cast-iron impeller are the primary wear parts; inspect the seal for leaks and the impeller vanes for erosion during annual maintenance.
At what head does the 1 HP motor hit its thermal limit during continuous 230 V operation?
At 40 ft of head the flow drops to 51.0 gpm and the motor draws 10.20 A, indicating the practical limit for sustained running without overheating.