We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Zoeller

Zoeller D293 1 HP 2" 230V Auto Submersible Sewage Pump Trap

SKU CH-58T1-QH4Y8 MPN D293

1 HP submersible sewage pump moves 122.0 gpm at 15 ft head with vertical float switch and 2 in solids handling

  • TypeDrain Components
  • Handles 2-inch solids for reliable waste removal
  • 1 HP motor delivers 122.0 gpm at 15 ft head
  • Hermetically sealed oil-filled motor resists moisture ingress
  • Vertical float switch activates at 14 3/4 in on point
  • Cast iron construction withstands harsh sewage environments

1 HP 230 V Sewage Pump

The Zoeller D293 is a 1 HP submersible sewage pump built for 230 V single-phase supply. Its cast-iron body and impeller handle solids up to 2 in diameter. A hermetically-sealed, oil-filled motor and carbon-ceramic shaft seal protect internal components. The integral vertical float switch turns the pump on at 14 3/4 in and off at 5 in liquid level.

Residential and Light-Commercial Waste

This pump suits homes or small businesses that need to lift sewage from a basin to a gravity sewer or septic system. The 2 in discharge and 24 in minimum sump diameter match standard residential pits. Installations requiring higher flow at greater head, three-phase power, or a smaller basin should evaluate other models.

Vertical Float Switch Levels

The integral vertical float switch provides fixed actuation points: on at 14 3/4 in and off at 5 in. These levels determine the minimum basin depth and the pumping cycle volume. Buyers must verify that the pit depth and required cycle match these exact switch settings.

Highlights

  • Handles 2-inch solids for reliable waste removal
  • 1 HP motor delivers 122.0 gpm at 15 ft head
  • Hermetically sealed oil-filled motor resists moisture ingress
  • Vertical float switch activates at 14 3/4 in on point
  • Cast iron construction withstands harsh sewage environments

Specifications

TypeDrain Components
BrandZoeller
ModelD293

Questions about this item

How do I set the vertical float switch so the pump turns on at 14 3/4 in and off at 5 in without the tether snagging?

Mount the pump vertically in a pit at least 24 in wide, route the integral float cord clear of the discharge pipe, and verify the on point at 14 3/4 in and off point at 5 in before backfilling.

Which wear items on the carbon-ceramic shaft seal and cast-iron impeller should I plan to replace after extended service?

The carbon-ceramic shaft seal and cast-iron impeller are the primary wear parts; inspect the seal for leaks and the impeller vanes for erosion during annual maintenance.

At what head does the 1 HP motor hit its thermal limit during continuous 230 V operation?

At 40 ft of head the flow drops to 51.0 gpm and the motor draws 10.20 A, indicating the practical limit for sustained running without overheating.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.