Wiegmann
Wiegmann RSC060606G Galvanized Steel Enclosure 6 in line protection
Galvanized steel enclosure rated NEMA 3R for wall-mounted line protection, 16 ga with padlockable handle and clamps, 6 in usable depth, CSA and cULus listed
- TypeBus Plugs
- NEMA 3R rating shields equipment from rain and sleet
- 16-gauge galvanized steel resists corrosion in harsh environments
- Padlockable handle secures internal components against unauthorised access
- 88 in usable depth accommodates standard bus plugs
- cULus and CSA certifications confirm code-compliant safety
Compact wall-mount enclosure for line protection
The Wiegmann RSC060606G is a galvanised steel enclosure rated NEMA 3R for outdoor and indoor line-protection duties. Its 16-gauge construction and screw-on solid cover with clamps provide a secure, padlockable barrier around bus plugs or similar devices.
Passive thermal management in a sealed steel body
With no fans or active cooling, the enclosure relies on its galvanised finish and metal mass to dissipate heat from installed components. The solid cover and gasketed clamps maintain the 3R rating against rain and sleet while keeping noise at zero.
Fits standard wall-mount layouts
The 6-inch cube footprint and included mounting screws allow direct attachment to structural surfaces. A usable opening depth of 5.88 inches accommodates bus plugs without protruding, leaving the surrounding wall area clear for conduit runs or additional enclosures.
Highlights
- NEMA 3R rating shields equipment from rain and sleet
- 16-gauge galvanized steel resists corrosion in harsh environments
- Padlockable handle secures internal components against unauthorised access
- 88 in usable depth accommodates standard bus plugs
- cULus and CSA certifications confirm code-compliant safety
Specifications
| Brand | WIEGMANN |
|---|---|
| Type | Bus Plugs |
Questions about this item
How do I mount the RSC060606G enclosure to the wall, and what step is often missed?
Use the built-in mounting holes on the back of the 16 ga galvanized steel body; the step often missed is tightening the included screws evenly to maintain the NEMA 3R seal.
What part of the RSC060606G will need maintenance or replacement over time?
The clamps and padlockable handle on the screw-on cover should be inspected periodically; replace them if corrosion prevents a tight closure on the solid cover.
What is the first limit reached when the RSC060606G is used continuously in a hot environment?
The usable opening depth of 5.88 in limits the size of internal components, so heat buildup inside the 6 in deep enclosure becomes the limiting factor first.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.