Wiegmann
Wiegmann AF0404 Wireway Telescope Fitting 4x4 in 9.50-15.00 in Steel Gray
Adjustable steel fitting extends 9.50 to 15.00 inches for 4x4 wireway runs, NEMA 1 rated with powder-coated gray finish
- TypeCable Management & Conduit
- ColorGray
- Telescopic adjustment covers 9.50 in to 15.00 in length
- NEMA Type 1 rating suits indoor wireway runs
- Powder-coated steel resists corrosion in dry locations
- 16 ga. steel construction adds rigidity to the fitting
- cULus listing confirms compliance with safety standards
Wireway Telescope Fitting for 4x4 Systems
This adjustable fitting connects wireway sections in commercial electrical installations. It spans a length of 9.50 in to 15.00 in and carries a NEMA 1 rating for indoor use. The 16 ga steel body has a powder-coated gray finish for corrosion resistance. A hinged screw-on cover secured by duct clips allows straightforward access to cables.
Installers Using HS or S Series Wireways
The fitting is built specifically for 4 in by 4 in HS Series and S Series wireways, so it suits electricians working with that exact profile. It will not align with wireways of different widths, heights or knockout patterns. Buyers needing a fixed-length coupling or a fitting with knockouts should select a different component.
Adjustable Length Range 9.50 to 15.00 in
The telescoping design lets you bridge variable gaps between wireway runs without cutting custom pieces. This single dimension determines whether the fitting can span the distance in your layout. Verify the required extension before ordering to ensure proper fit.
Highlights
- Telescopic adjustment covers 9.50 in to 15.00 in length
- NEMA Type 1 rating suits indoor wireway runs
- Powder-coated steel resists corrosion in dry locations
- 16 ga. steel construction adds rigidity to the fitting
- cULus listing confirms compliance with safety standards
Specifications
| Brand | WIEGMANN |
|---|---|
| Type | Cable Management & Conduit |
| Color | Gray |
Questions about this item
Does the 16-gauge steel fitting generate any heat or noise during continuous use?
The fitting is a passive steel component with no moving parts, so it produces no heat or noise during operation.
What existing wireway system is required for the AF0404 to connect properly?
It is designed for use with HS Series and S Series wireways that have a 4 in by 4 in cross-section.
Will the adjustable 9.50 in to 15.00 in length align with older 4x4 wireway sections?
Yes, the telescopic range bridges gaps between existing 4 in by 4 in wireway runs while maintaining NEMA 1 enclosure integrity.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



