Watts 3/4 LF 3005-3/4A Dielectric Union Trap
Connects 3/4-inch male NPT and male solder joints with brass and zinc-plated steel construction rated for 250 psi and 33 to 180 degrees F
- TypeDrain Components
- Prevents galvanic corrosion with brass and zinc-plated steel construction
- Withstands 250 psi maximum operating pressure for reliable service
- Operates from 33 to 180 degrees F for hot and cold lines
- Polysulfone insulator and Buna-N gasket ensure dielectric isolation
- 3 inch overall length fits standard 3/4 inch connections
Dielectric Union for Dissimilar Metals
The Watts 3/4 LF 3005-3/4A dielectric union connects 3/4 inch male NPT threads to a 3/4 inch male solder joint. It prevents galvanic corrosion between dissimilar piping metals in plumbing and hydronic heating systems. The union is rated for a maximum operating pressure of 250 psi.
Brass Body with Polysulfone Insulator
A brass body and zinc-plated galvanized steel nut provide mechanical strength while the polysulfone insulator electrically isolates the joint. The Buna-N gasket creates a reliable seal across the operating temperature range of 33 to 180 degrees F. These materials work together to maintain the dielectric break over time.
Compact Three-Inch Installed Length
At 3 inches overall length the union fits into tight piping runs without requiring extra clearance. Male threads on one end and a solder cup on the other allow direct transition between threaded and sweat connections. The design supports straightforward installation in new work or repair scenarios.
Highlights
- Prevents galvanic corrosion with brass and zinc-plated steel construction
- Withstands 250 psi maximum operating pressure for reliable service
- Operates from 33 to 180 degrees F for hot and cold lines
- Polysulfone insulator and Buna-N gasket ensure dielectric isolation
- 3 inch overall length fits standard 3/4 inch connections
Specifications
| Type | Drain Components |
|---|---|
| Brand | Watts |
| Model | 3/4 LF 3005-3/4A |
Questions about this item
Will the Buna-N gasket need periodic replacement?
The Buna-N gasket can degrade over time and should be inspected during routine system maintenance; replacement intervals depend on water chemistry and temperature cycling.
What pressure limit governs continuous operation?
The union is rated for a maximum operating pressure of 250 psi; sustained pressure at or near this value may accelerate gasket wear.
How hot does the polysulfone insulator get during all-day service?
The insulator is rated for continuous exposure up to 180 °F; in normal plumbing loops it remains close to the fluid temperature.