Vszerda
Vszerda FP-108EX-S1-B rotary fan AC 220/240V 38W 172x150x51mm
AC 220/240 V rotary fan with ball bearing, 38 W, 2700-3100 min⁻¹, 172×150×51 mm
- Runs on standard 220/240 VAC mains without extra adapters
- Ball-bearing motor rated for 2700–3100 rpm continuous operation
- Compact 172 × 150 × 51 mm frame fits tight enclosures
- Operates reliably from −25 °C to 60 °C ambient temperature
- Draws only 38 W at 0.22 A for efficient cooling
Industrial Rotary Fan AC 220/240V
The Vszerda FP-108EX-S1-B is a 38 W AC rotary fan built for equipment enclosures and machinery cooling. It operates on 220–240 V mains at 50/60 Hz and draws 0.22 A. The unit suits installers who need a compact, hard-wired airflow device for industrial cabinets.
Ball-Bearing Thermals 2700–3100 min⁻¹
Ball bearings support a speed range of 2700–3100 min⁻¹ across an ambient window of -25 °C to 60 °C. Power draw remains at the rated 38 W during continuous operation. The two-lead wire connection simplifies integration into existing 220 VAC control circuits.
Two-Lead Wire Mounting 172x150x51 mm
The package supplies only the fan unit measuring 172×150×51 mm with two lead wires for direct wiring. No brackets, guards, speed controllers or software are included. Buyers requiring plug-in connectors, PWM control or filtered intake must source those separately.
Highlights
- Runs on standard 220/240 VAC mains without extra adapters
- Ball-bearing motor rated for 2700–3100 rpm continuous operation
- Compact 172 × 150 × 51 mm frame fits tight enclosures
- Operates reliably from −25 °C to 60 °C ambient temperature
- Draws only 38 W at 0.22 A for efficient cooling
Specifications
No published specifications for this item yet.
Questions about this item
How do I wire the two-lead power connection on the FP-108EX-S1-B?
Connect the two leads directly to a 220-240 VAC 50/60 Hz supply; the unit draws 0.22 A at 38 W. The step often missed is confirming the circuit can handle the inrush current at start-up.
Which part of the FP-108EX-S1-B will need replacement first?
The ball bearing is the only moving component subject to wear; it determines the fan's service life under continuous operation.
What thermal limit affects the FP-108EX-S1-B during sustained use?
The rated ambient temperature range is -25 °C to 60 °C; operating above 60 °C is the first limit that will degrade performance or stop the motor.