Viega
Viega ProPress 2918 Copper Reducing Tee 2" x 2" x 1
Copper reducing tee joins 2-inch and 1-inch lines with press-fit connections rated to 200 psi
- Reduces pipe diameter with 2" to 1" transition
- Press-fit connections install without soldering tools
- EPDM O-ring seals potable water systems
- Rated for 200 psi operating pressure
- Rolled centre stop ensures correct insertion depth
Copper Reducing Tee 2" x 2" x 1
This Viega ProPress 2918 fitting joins three copper tubes in a reducing tee configuration. Two branches accept 2 in copper tube size while the third accepts 1 in. The rolled centre stop and EPDM O-ring create a secure press-fit seal for potable water systems.
Thermals Noise and Power Draw
As a passive copper fitting, it generates no heat, produces no noise and draws no power during normal operation. The joint relies on mechanical press-fit force rather than electrical energy. Performance depends on correct installation pressure and tube preparation.
Maximum Operating Pressure 200 psi
The fitting is rated for a maximum operating pressure of 200 psi in potable water applications. Installers must verify that system pressure does not exceed this limit. It is not suitable for systems that require higher pressure ratings or non-potable fluid compatibility.
Highlights
- Reduces pipe diameter with 2" to 1" transition
- Press-fit connections install without soldering tools
- EPDM O-ring seals potable water systems
- Rated for 200 psi operating pressure
- Rolled centre stop ensures correct insertion depth
Specifications
| Brand | Viega |
|---|
Questions about this item
How is the Viega ProPress 2918 reducing tee installed, and what step do people often get wrong?
Insert each tube fully until it hits the rolled center stop, then press with a compatible ProPress jaw; the common error is stopping short of the stop, which leaves the EPDM O-ring unseated and causes leaks.
What maintenance or replacement will this copper tee need later?
The EPDM O-rings inside the press sockets can degrade over time; if a joint begins to weep, the fitting must be cut out and a new tee pressed in — O-rings are not field-replaceable.
What limit appears first under sustained pressure use?
The maximum operating pressure is 200 psi; sustained operation above that rating will stress the copper body and O-ring seals before any other factor.