VEVOR CW6000 1500W Industrial Water Chiller 15L 65 L/min
Industrial water chiller with 1500 W rated power, 15 L tank and 65 L/min maximum flow for cooling up to two 300 W CO₂ laser tubes
- TypeOther Appliances
- Cools two 300 W laser tubes efficiently
- 5 kW cooling capacity removes heat fast
- 600 W pump delivers 65 L/min flow
- 15 L tank sustains cooling longer
- 6 lb carbon-steel frame built for industrial use
Industrial Water Chiller for CO2 Laser Systems
The VEVOR CW6000 is a 1500W industrial water chiller built to cool CO2 laser engraving and cutting machines. It supports up to two 300W laser tubes with a rated cooling capacity of 3585W. The unit suits workshops that need continuous temperature control for high-power laser operations.
Bundled Installation Kit Speeds Setup
The package includes a 13 ft water hose, four sealing hoops, Teflon tape, an aviation plug and a user manual. These parts let you connect the 16 mm inlet and outlet ports to your laser system without sourcing extra fittings. The 600W pump delivers up to 65 L/min flow for immediate circulation.
Verify Power, Space and Fluid Compatibility
Confirm your facility can supply the rated 1500W power draw and accommodate a 52 kg unit measuring 114.6 lbs. The 15 L tank requires clean water or approved coolant; check that your laser tubes accept the 0.6 in port diameter. Ensure ventilation clearance for the compressor-based cooling system.
Highlights
- Cools two 300 W laser tubes efficiently
- 5 kW cooling capacity removes heat fast
- 600 W pump delivers 65 L/min flow
- 15 L tank sustains cooling longer
- 6 lb carbon-steel frame built for industrial use
Specifications
| Type | Other Appliances |
|---|
Questions about this item
How often will the 15 L water tank need refilling or coolant replacement during continuous operation?
The clear observation window lets you monitor the level in the 15 L tank so you can top up before the pump runs dry; distilled water or approved coolant should be changed according to the laser manufacturer's schedule, typically every few months.
What component reaches its limit first when the chiller runs at the 3585 W cooling capacity for long periods?
The 600 W pump is rated for a maximum flow of 65 L/min, so sustained demand at the full 3585 W cooling load will hit the pump's flow ceiling before the compressor reaches its thermal limit.
How much heat and power does the unit add to the room when it runs all day at 1500 W rated power?
At the rated 1500 W input the chiller rejects roughly that same energy as heat into the surrounding air, so the room gains about 1.5 kW of warmth while the compressor and 600 W pump operate continuously.