VEVOR
VEVOR 1U PDU 8 Outlets 19in 15A 1800J 110-125V
A 1U rack-mount power strip with eight NEMA 5-15R outlets, a 15 A rating and 1800 J surge protection for 19-inch server racks
- TypeOther Appliances
- 1U rack-mount design fits 19-inch server cabinets
- 8 NEMA 5-15R outlets power multiple devices at once
- Integrated switch controls all outlets with one touch
- 1800 J surge protector absorbs voltage spikes
- 15 A resettable breaker cuts power on overload
Rack-Mount Power Distribution
The VEVOR 1U PDU fits a standard 19-inch server rack and provides eight NEMA 5-15R outlets for connected equipment. It accepts AC input between 110 and 125 volts at 60 hertz and supports a maximum output current of 15 amps. The unit mounts in a single rack unit and includes four screws for installation.
Integrated Protection and Switch
A built-in surge protector rated at 1800 joules absorbs voltage spikes, while an external resettable breaker cuts power during overloads or short circuits. An integrated switch controls all eight outlets simultaneously with one touch. The package includes a user manual along with the mounting hardware.
Pre-Installation Checks
Verify that your rack uses 19-inch mounting rails and has 1U of free vertical space. Confirm that the facility supply voltage falls within the 110 to 125 volt range and that the total connected load will not exceed 15 amps. Ensure each device uses a compatible NEMA 5-15P plug for the outlets provided.
Highlights
- 1U rack-mount design fits 19-inch server cabinets
- 8 NEMA 5-15R outlets power multiple devices at once
- Integrated switch controls all outlets with one touch
- 1800 J surge protector absorbs voltage spikes
- 15 A resettable breaker cuts power on overload
Specifications
| Type | Other Appliances |
|---|
Questions about this item
Will the 1800 J surge protector need replacing after a big spike?
The 1800 J MOV absorbs surges until its energy budget is exhausted; a massive hit can degrade it, so plan to swap the unit if the protection indicator goes out or after a known lightning event.
What trips first when the rack draws close to 15 A continuously?
The external resettable breaker opens at 15 A, cutting power before the 15 A cord or outlets overheat.
How hot or loud does the strip get when all eight outlets run all day?
No fan is fitted, so it runs silent; warmth stays low unless you approach the 15 A limit, at which point the metal chassis may feel warm.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.