We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Vertiv

Vertiv PD5-002 accessory: 2×L6-20R, 2×5-15/20R, L14-30P in

SKU CH-3S90-YPEP2 MPN PD5-002

A power output distribution module with maintenance bypass provides two L6-20R and two 5-15/20R outlets from an L14-30P input for continuous uptime during UPS servicing

  • TypeModule
  • SpecificationsOutput: two (2) NEMA L6-20R, two (2) NEMA 5-15/20R Input: NE
  • FeaturesFlexibility: provide flexibility to your ups with this power
  • Maintains power during UPS servicing with built-in maintenance bypass
  • Distributes power to four outlets: two L6-20R and two 5-15/20R
  • Connects to utility or generator via L14-30P input
  • Plug-and-play deployment keeps critical loads online without rewiring
  • Automatically transfers load to utility power if UPS fails

Power Distribution for GXT5 UPS

The Vertiv PD5-002 module connects a Liebert GXT5 UPS to connected equipment through four output receptacles. Two NEMA L6-20R outlets and two NEMA 5-15/20R outlets accept a mix of locking and straight-blade plugs. The unit draws input power through a single NEMA L14-30P connector. It is built for network managers who need to keep servers, switches and peripherals powered during UPS servicing.

Maintenance Bypass Operation

A built-in maintenance bypass switch transfers the load from the UPS to utility power without interrupting connected devices. This allows technicians to service or replace the UPS while critical operations continue. The plug-and-play design requires no hardwiring, so deployment is fast and does not demand an electrician. The transfer mechanism protects equipment from rare accidental UPS failures by providing an immediate alternative power path.

Upgrade From Basic PDUs

This module replaces a standard power distribution strip that lacks a bypass function. The jump is worth it when uptime requirements forbid any shutdown for UPS maintenance or battery replacement. It is not for installations that can schedule a full power-down window or for sites that do not use a compatible Liebert GXT5 UPS as the upstream source.

Highlights

  • Maintains power during UPS servicing with built-in maintenance bypass
  • Distributes power to four outlets: two L6-20R and two 5-15/20R
  • Connects to utility or generator via L14-30P input
  • Plug-and-play deployment keeps critical loads online without rewiring
  • Automatically transfers load to utility power if UPS fails

Specifications

BrandVertiv
ModelPD5-002
TypeModule
SpecificationsOutput: two (2) NEMA L6-20R, two (2) NEMA 5-15/20R
Input: NEMA L14-30P
FeaturesFlexibility: provide flexibility to your ups with this power output distribution unit that has built-in ups maintenance bypass feature
Continuous uptime: easy plug-and-play deployment To ensure continuous uptime of your network even during ups maintenance
Layer of protection: The pod automatically transfers current from the UPS to utility power to protect your critical Operations from rare accidental ups failures
Shipping weight6.80 kg
Package size526 × 241 × 231 mm

Questions about this item

How do I install the Vertiv PD5-002 with the L14-30P input and the four output receptacles?

Connect the L14-30P plug to a matching 30 A utility receptacle, then plug the UPS input into the module and attach loads to the two L6-20R and two 5-15/20R outlets. The step often missed is wiring the UPS output to the module before energising the bypass switch.

What maintenance will the PD5-002 maintenance bypass module need over time?

The unit has no user-serviceable parts or batteries. Periodic inspection of the L14-30P plug, the four output receptacles and the bypass switch contacts for heat discolouration or looseness is the only upkeep required.

Which limit appears first when the PD5-002 runs continuously at full load?

The 30 A L14-30P input rating is the first hard limit; total connected load must stay at or below 30 A per phase to avoid tripping the upstream breaker.