Vertiv
Vertiv PD2-101 PDU 10-Outlet 60A 208/120V 2xL6-30R 8x5-20R
A 10-outlet PDU delivering 60 A at 208/120 V with two L6-30R and eight 5-20R receptacles, hardwired via a four-wire terminal block
- TypeOthers
- FeaturesProduct Name:PD2-101 10-Outlets PDU Output Receptacles:2 x N
- Weight4.40 lb
- 60 A capacity powers dense rack loads
- 10 outlets combine 2 x L6-30R and 8 x 5-20R
- Hardwire 3-wire plus ground input simplifies installation
- 208/120 V split-phase suits mixed-voltage gear
- Light 4.40 lb chassis eases rack mounting
Power Distribution Unit for 60 A three-phase input
The Vertiv PD2-101 is a rack-mount power distribution unit that accepts a hard-wired 208/120 V three-phase feed rated at 60 A. It provides ten output receptacles: two NEMA L6-30R locking outlets and eight NEMA 5-20R straight-blade outlets. The unit weighs 4.40 lb and is sold new.
Suited for mixed-voltage racks.
This PDU fits data-centre racks that need both 30 A locking and 20 A standard circuits from a single three-phase drop. It does not suit operators who require a cord-and-plug input connection or who need more than ten output connections. Buyers without three-phase service should look elsewhere.
Hard-wire feed frees rack space for ten devices
The hard-wire terminal block eliminates an inlet cord, leaving more room in the cabinet for the ten connected loads. Two L6-30R outlets serve high-draw equipment while eight 5-20R outlets handle standard servers or accessories. Ensure the upstream breaker and wiring match the 60 A rating.
Highlights
- 60 A capacity powers dense rack loads
- 10 outlets combine 2 x L6-30R and 8 x 5-20R
- Hardwire 3-wire plus ground input simplifies installation
- 208/120 V split-phase suits mixed-voltage gear
- Light 4.40 lb chassis eases rack mounting
Specifications
| Brand | Liebert |
|---|---|
| Model | PD2-101 |
| Type | Others |
| Features | Product Name:PD2-101 10-Outlets PDU Output Receptacles:2 x NEMA L6-30R 8 x NEMA 5-20R Number of Output Connections:2 8 Product Type:PDU Current:60 A Input Receptacles:Hardwire Terminal Block 3W + G |
| Weight | 4.40 lb |
| Shipping weight | 2.79 kg |
| Package size | 523 × 308 × 232 mm |
Questions about this item
What hard-wire supply does the PD2-101 require for its 60 A rating?
The unit needs a 208/120 V three-phase plus ground feed wired into its terminal block.
Can the eight NEMA 5-20R outlets and two NEMA L6-30R outlets be used at the same time?
Yes, all ten receptacles are live simultaneously up to the 60 A total limit.
How do I verify the PDU is delivering power after installation?
Plug a known-good load into each 5-20R and L6-30R outlet and confirm the equipment powers on.