Vertiv
Vertiv Liebert GXT5-500LVRT2UXLN 500VA 120V UPS 2U Rack/Tower 6x NEMA 5-15R
A 500 VA online UPS with six NEMA 5-15R outlets, 2U rack/tower form factor and included network card
- International Version120V
- Input Voltage Range60-150V
- Input Frequency40-70Hz; Auto Sensing
- Input ConnectionNEMA 5-15P
- VA Rating500VA
- Watts500W
- Zero transfer time protects sensitive loads instantly
- 500VA 500W double-conversion topology delivers clean 120V output
- 6 NEMA 5-15R outlets power multiple devices from one unit
- RDU120 network card enables remote monitoring and management
- 2U rack or tower form factor fits diverse installations
500VA Online UPS for Mission-Critical Equipment
The Vertiv Liebert GXT5-500LVRT2UXLN is a 500VA double-conversion UPS delivering 500W of continuous output power. It provides zero-transfer-time protection for mission-critical servers, networking gear and sensitive electronics. The unit accepts a wide 60-150V input range and supplies user-configurable 110/115/120/125VAC output with +/-3% regulation.
2U Rack/Tower Mount with Network Card Included
Installation fits a standard 2U rack space or stands as a tower using the included hardware. The 10 ft input cord terminates in a NEMA 5-15P plug for a standard 120V branch circuit. Six NEMA 5-15R receptacles are on the rear panel. The factory-fitted RDU120 network card enables remote monitoring via SNMP and web browser without an extra accessory.
VRLA Battery Delivers 17.9 Minutes at Full Load
The internal valve-regulated lead-acid battery recharges to full capacity in three hours. Runtime is 17.9 minutes at 500W load and 40.4 minutes at half load. Operating temperature range is 32°F to 104°F with humidity tolerance up to 95% non-condensing. The unit carries UL 1778 4th Edition and CSA 22.2 No 107.3 safety approvals.
Highlights
- Zero transfer time protects sensitive loads instantly
- 500VA 500W double-conversion topology delivers clean 120V output
- 6 NEMA 5-15R outlets power multiple devices from one unit
- RDU120 network card enables remote monitoring and management
- 2U rack or tower form factor fits diverse installations
Specifications
| Brand | Vertiv |
|---|---|
| Series | Liebert |
| Model | GXT5-500LVRT2UXLN |
| International Version | 120V |
| Input Voltage Range | 60-150V |
| Input Frequency | 40-70Hz; Auto Sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 500VA |
| Watts | 500W |
| Output Voltage | 110/115/120/125VAC; (user-configurable); +/-3% |
| Outlets | 6 |
| Outlet Type | 6 x NEMA 5-15R |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Half Load: 40.4 min Full Load: 17.9 min |
| Approvals | UL 1778 4th Edition and CSA 22.2 No 107.3 |
| Temperature | Operating Temperature: 32°F - 104°F (0°-40°) Storage Temperature: -4°F - 140°F (-20°-60°) |
| Humidity | 0% to 95%, non-condensing |
| Dimensions | 3.4" x 16.9" x 15.7" |
| Weight | 37 lbs. |
| Package Contents | with RDU120 Network Card |
| Shipping weight | 23.12 kg |
| Package size | 623 × 572 × 271 mm |
Questions about this item
How do I verify the UPS is operating correctly after installation?
Check the LCD for normal mode, confirm output voltage reads 110/115/120/125VAC, ensure the SNMP/Webcard shows reachable via network, and run a self-test to validate battery health.
What comes in the box and what must I purchase separately?
The package includes the 2U rack/tower UPS, an installed RDU120 network card, a 10 ft NEMA 5-15P input cord, and rail hardware; no extra cables or batteries are required for basic operation.
Should I select the 500 VA model or a higher VA unit for my load?
This unit delivers 500 VA / 500 W with 17.9 min runtime at full load and 40.4 min at half load; choose a higher VA model only if your equipment exceeds 500 W.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.