Value Brand
Value Brand Vacuum Gauge Liquid Filled 3-1/2 In
Measures vacuum from -30 to 0 in Hg with a liquid-filled, 304 stainless steel case for steady readings
- TypeElectronic
- Liquid-filled design dampens needle vibration for steady readings
- Dual-scale dial shows vacuum in in Hg and kPa simultaneously
- Stainless-steel case and wetted parts resist corrosion in harsh environments
- Center-back 1/4 in MNPT connection suits panel mounting
- Accuracy rated at ±3-2-3 % across full -30 to 0 in Hg range
Vacuum Gauge 3-1/2 In Liquid Filled
This liquid-filled vacuum gauge measures negative pressure from -30 to 0 in Hg with a secondary scale of -100 to 0 kPa. It uses a 1/4 in MNPT center-back connection and a 304 stainless steel case for corrosion resistance. Accuracy is rated at +/-3-2-3 percent across the range.
General Purpose Vacuum Testing
The gauge suits technicians checking HVAC, refrigeration or automotive systems where a damped needle eases reading under vibration. It is not for applications requiring a calibration certificate, panel mounting, positive-pressure measurement or a digital output.
304 Stainless Steel Wetted Parts
All wetted components are 304 stainless steel, so the gauge withstands common non-corrosive gases and liquids in general-purpose service. Buyers needing other alloys for aggressive media should select a different model.
Highlights
- Liquid-filled design dampens needle vibration for steady readings
- Dual-scale dial shows vacuum in in Hg and kPa simultaneously
- Stainless-steel case and wetted parts resist corrosion in harsh environments
- Center-back 1/4 in MNPT connection suits panel mounting
- Accuracy rated at ±3-2-3 % across full -30 to 0 in Hg range
Specifications
| Brand | ZORO SELECT |
|---|---|
| Type | Electronic |
Questions about this item
Does the liquid-filled gauge need the fill fluid replaced over time?
The gauge is liquid-filled at the factory; the sealed 304 stainless case and wetted parts are designed for long-term use without refilling.
What is the accuracy limit when the needle is held at deep vacuum for long periods?
Accuracy is rated at +/-3-2-3 percent of full scale across the -30 to 0 in Hg primary range and -100 to 0 kPa secondary range.
How much heat does the gauge generate when mounted on a panel running continuously?
As a passive mechanical instrument with no electronics, it produces no measurable heat during all-day operation.