Value Brand
Value Brand Electric Heating Cable 120VAC 100 ft Red
Non-regulating electric heating cable delivers 300 W at 40 °F across 100 ft of copper conductor with PVC cover
- ColorRed
- Delivers 300 W of heat at 40 °F
- Operates on standard 120 V AC household power
- Non-regulating design provides constant output along full 100 ft length
- PVC jacket protects copper conductors up to 221 °F max temperature
- Hardwired installation with 2-conductor cable rated for 2.5 A total current
Purpose & Audience
This 100‑foot electric heating cable operates at 120 VAC and delivers 3 watts per foot at 40 °F for a total of 300 watts. It is designed for indoor, hard‑wired installations such as pipe freeze protection or roof‑edge de‑icing where a constant‑wattage, non‑regulating trace is required.
Who It Suits & Who Should Look Elsewhere
Installers who need a simple, single‑phase copper cable with PVC jacket and a maximum circuit length of 250 ft will find it a direct fit. Buyers who need self‑regulating output that adjusts with temperature, outdoor‑rated construction, or a plug‑and‑play connector should look elsewhere.
Capacity & Headroom
At 40 °F the cable draws 2.5 amps overall, or 0.025 amps per foot, and can maintain operation up to 221 °F. The 250‑ft maximum circuit length gives headroom for longer runs, while the fixed 3‑watt‑per‑foot output means heat does not decrease in warmer sections.
Highlights
- Delivers 300 W of heat at 40 °F
- Operates on standard 120 V AC household power
- Non-regulating design provides constant output along full 100 ft length
- PVC jacket protects copper conductors up to 221 °F max temperature
- Hardwired installation with 2-conductor cable rated for 2.5 A total current
Specifications
| Brand | ZORO SELECT |
|---|---|
| Color | Red |
Questions about this item
Does this 100 ft cable require a thermostat or controller to operate safely?
The cable is non-regulating, so it delivers constant 3 W per foot at 40°F. A separate thermostat or controller must be installed to cycle power and prevent overheating.
Can I run this 120 V cable on the same circuit as older 120 V heat trace without exceeding the 250 ft maximum circuit length?
Total combined length on one circuit must stay within the 250 ft maximum; verify the existing run length before adding this 100 ft cable.
How can I confirm the cable is drawing the expected 2.5 A at 40°F after installation?
Clamp a multimeter on the supply leads; a reading near 2.5 A per cable at 40°F indicates the 300 W output is active.