We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Value Brand

Value Brand 6UEC5 Limit Rollout HVAC Control 220F Manual Reset

SKU CH-JG8W-317R2

Surface-mount flame rollout limit controller opens at 220 °F with manual reset and operates on 120 V or 240 V AC

  • Opens at 220°F to stop flame rollout
  • Manual reset prevents automatic restart after trip
  • SPST contact opens on temperature rise
  • Rated for 120V and 240V AC input
  • Surface mount with 1 1/4 in base length

Temperature Limit Controller for Flame Rollout

This surface-mount temperature limit controller is built for HVAC systems that require flame-rollout protection. It uses an SPST contact that opens on temperature rise and requires a manual reset once tripped. The unit operates on 120V AC or 240V AC input voltage. It mounts with a base measuring 1 1/4 in by 3/4 in.

Suited for manual-reset safety circuits.

This control suits technicians and installers who need a manual-reset limit switch that opens at 220 Degrees F. It is not suitable for applications that require an automatic reset function or a defined closing temperature. Buyers needing adjustable temperature differentials or a maximum control temperature setting should look elsewhere.

Opens at 220 Degrees F with manual reset

The single specification that decides fit is the switch opening temperature of 220 Degrees F combined with a manual reset type. The contact opens on rise and stays open until physically reset. Verify that your system requires this exact opening temperature and reset method before installation.

Highlights

  • Opens at 220°F to stop flame rollout
  • Manual reset prevents automatic restart after trip
  • SPST contact opens on temperature rise
  • Rated for 120V and 240V AC input
  • Surface mount with 1 1/4 in base length

Specifications

BrandZORO SELECT

Questions about this item

How do I verify the limit rollout switch is operating correctly after installation?

Apply heat until the switch reaches 220 degrees Fahrenheit; the SPST contacts should open and remain open until the manual reset button is pressed.

What components are included and what must be sourced separately?

The package contains the surface-mount temperature limit controller with a 1 1/4 inch by 3/4 inch mounting base; wiring, connectors and mounting hardware are not included.

Which voltage rating should I select for a 240 V AC supply?

The controller is rated for both 120 V AC and 240 V AC inputs, so the same unit works with either supply voltage.