Adjustable surface-mount limit controller with automatic reset, SPST contacts opening at 135–215 °F and rated for 120/240 V AC
- Adjustable 135-215 °F range suits varied HVAC needs
- Auto reset restores operation without manual intervention
- SPST open-on-rise protects equipment on over-temperature
- Dual 120/240 V AC input fits common supply voltages
- Compact 2 in × 1 3/4 in base allows surface mounting
Adjustable Temperature Limit Controller
The Value Brand 6UDY5 is a surface-mount temperature limit controller designed for HVAC systems requiring automatic reset protection. It operates on 120V AC or 240V AC input voltage with a single-pole single-throw contact that opens on temperature rise.
Surface Mount Installation Details
The unit mounts on a 2 in by 1 3/4 in base using surface-mount hardware. Common issues include wiring the SPST contacts incorrectly for the open-on-rise action or selecting a voltage mismatch between the 120V AC and 240V AC supply.
Pre-Order Compatibility Checks
Verify that your system requires an adjustable limit range between 135 Degrees F and 215 Degrees F with automatic reset behaviour. Confirm the control circuit voltage matches either 120V AC or 240V AC and that the mounting surface accommodates the stated base dimensions.
Highlights
- Adjustable 135-215 °F range suits varied HVAC needs
- Auto reset restores operation without manual intervention
- SPST open-on-rise protects equipment on over-temperature
- Dual 120/240 V AC input fits common supply voltages
- Compact 2 in × 1 3/4 in base allows surface mounting
Specifications
| Brand | ZORO SELECT |
|---|
Questions about this item
How can I verify the controller is cycling correctly after installation?
Measure the switch terminals with a multimeter; the SPST contact should open when the sensed temperature reaches 175°F or 215°F and close again once it falls back to 135°F or 175°F.
What hardware is included with the 6UDY5 and what must I source separately?
The controller body and its 2 in by 1 3/4 in surface-mount base are supplied; you must provide 120 V AC or 240 V AC wiring, wire connectors and mounting screws.
Which temperature range should I select for a high-limit safety on a 240 V AC furnace?
Choose the 175 °F opening / 135 °F closing set if the safety limit is near 175 °F, or the 215 °F opening / 175 °F closing set for a higher limit; both operate on 240 V AC.