Value Brand
Value Brand 4WRA6 Modular Extension Test Leads CAT III 1000V CAT IV 600V
Modular extension test leads rated CAT III 1000V and CAT IV 600V with shrouded banana plugs and double insulation
- TypeAssortments & Kits
- CAT III 1000V and CAT IV 600V ratings protect against high-energy transients
- Double insulation on 18 AWG wire reduces shock risk during measurements
- Shrouded banana plugs fit any meter with standard 4 mm inputs
- 10 A current capacity handles demanding automotive and electrical tests
- Includes couplers to extend reach by 1 ft 8 in for flexible access
Modular Extension Test Leads
The Value Brand 4WRA6 kit provides two modular extension leads for use with any multimeter, clamp meter or test instrument that accepts a standard shrouded banana plug. The set includes couplers and is rated for CAT III 1000V and CAT IV 600V measurement categories, making it suitable for professional electrical testing environments.
CAT III 1000V CAT IV 600V Rating
Each lead features double insulation and 18 AWG wire, supporting a maximum current of 10 A at up to 1000 V. The shrouded banana plug connections ensure secure attachment to instruments while maintaining the safety ratings required for industrial and utility applications.
Extending Existing Test Lead Reach
These 1 ft 8 in extensions are designed for technicians who need additional reach between their meter and the test point without replacing their primary lead set. They are not intended for users who require longer fixed-length leads or higher current capacity beyond the 10 A rating.
Highlights
- CAT III 1000V and CAT IV 600V ratings protect against high-energy transients
- Double insulation on 18 AWG wire reduces shock risk during measurements
- Shrouded banana plugs fit any meter with standard 4 mm inputs
- 10 A current capacity handles demanding automotive and electrical tests
- Includes couplers to extend reach by 1 ft 8 in for flexible access
Specifications
| Brand | ZORO SELECT |
|---|---|
| Type | Assortments & Kits |
Questions about this item
How do I connect the 18 AWG leads to my meter without a loose fit?
Push each shrouded banana plug straight into the meter jack until it clicks; the shroud locks the connection so vibration will not pull it out during use.
What part of the kit will wear out first and need replacing?
The double-insulation on the 18 AWG wire can crack after repeated bending; inspect the insulation before every job and replace the lead set if any conductor is visible.
At what point does the 10 A current rating become the limiting factor during a long test?
Sustained current above 10 A will heat the 18 AWG conductors past their safe limit, so the lead set must be derated or swapped for heavier leads before that threshold is reached.