We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Value Brand

Value Brand 12 AWG GPT Primary Wire Green Stranded Copper 60 V 500 ft

SKU CH-330F-YENE8

Green 12 AWG stranded copper primary wire on a 500 ft spool, rated 60 V for automotive circuits

  • TypeWire & Cable
  • 12 AWG stranded copper carries up to 60 V reliably
  • Green PVC insulation resists abrasion and chemicals
  • 500 ft spool covers long automotive runs
  • Single-conductor GPT design simplifies wiring jobs
  • Meets Grote 87-6506 primary wire specification

12 AWG GPT Primary Wire

This 12 AWG GPT primary wire uses stranded copper conductors with PVC insulation rated for 60 V. The green jacket identifies the conductor in automotive and industrial wiring harnesses. A 500 ft spool provides continuous length for long runs without splices.

Suited for low-voltage automotive circuits

Installers running lighting, accessory or sensor circuits at 60 V or below will find the stranded construction flexible enough for tight routing. The single-conductor design is not intended for multi-core cable assemblies or high-voltage distribution panels. Buyers who need shielded or multi-conductor cable should look elsewhere.

Fits standard automotive wiring looms

The wire terminates with common crimp terminals and fits typical loom sleeves and conduit used in vehicle builds. Stranded copper resists vibration fatigue better than solid core, reducing the risk of open circuits over time. The 500 ft length lets you cut exact lengths for each circuit, minimising waste and keeping the harness tidy.

Highlights

  • 12 AWG stranded copper carries up to 60 V reliably
  • Green PVC insulation resists abrasion and chemicals
  • 500 ft spool covers long automotive runs
  • Single-conductor GPT design simplifies wiring jobs
  • Meets Grote 87-6506 primary wire specification

Specifications

BrandGROTE
TypeWire & Cable

Questions about this item

What terminals or connectors do I need to terminate the 12 AWG stranded copper conductors?

Use crimp terminals or lugs rated for 12 AWG stranded copper; match the terminal barrel to the strand count and insulate with heat-shrink or electrical tape after crimping.

Can I pull this 12 AWG GPT wire through conduit that already carries 60 V circuits?

Yes, the PVC insulation is rated for 60 V, so it can share conduit with other 60 V conductors provided fill limits and temperature ratings are observed.

How do I verify the green 12 AWG GPT wire is intact after installation?

Perform a continuity test end-to-end with a multimeter and check for shorts to ground; the green PVC jacket should show no nicks or cuts along the 500 ft run.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.