Valiant Power
Valiant Power VP-PDU-30A-1U-8009 PDU 1U 240V 30A 10 C13 2 C19
A 1U rack-mount power distribution unit delivering 240V 30A through ten C13 and two C19 outlets with real-time volt and amp monitoring, 20kA surge suppression and dual 20A circuit breakers
- TypePower Distribution Units
- Rack Size1U
- Rack Mounting KitStandard 19inch
- CertificationsETL
- ROHSYes
- Package IncludesCage Nuts
- 20 kA surge suppression shields equipment from damaging spikes
- Real-time volt and amp meter shows live power draw
- Twelve outlets mix ten C13 and two C19 for dense deployments
- Two 20 A circuit breakers protect six outlets each
- Compact 1U 19-inch metal chassis fits standard racks
1U 240V 30A Rack PDU
This 1U power distribution unit delivers 240 volt, 30 amp capacity through ten C13 and two C19 outlets. It is built for data centres, networking closets and similar IT environments that need high-density power in a single rack space.
Upgrade from basic power strips
The unit replaces unmonitored strips by adding a volt and amp meter plus 20kA surge suppression. The jump is worth it when uptime matters and you need real-time visibility of load across two 20A circuit-breaker banks.
Fits 19-inch racks with L6-30P input
A ten-foot locking cord connects to a 200-240V 30A supply, while cage nuts secure the metal chassis in a standard 19-inch cabinet. The compact 1U height leaves space for servers and switches, and the mixed outlet count frees you from adapter cables.
Highlights
- 20 kA surge suppression shields equipment from damaging spikes
- Real-time volt and amp meter shows live power draw
- Twelve outlets mix ten C13 and two C19 for dense deployments
- Two 20 A circuit breakers protect six outlets each
- Compact 1U 19-inch metal chassis fits standard racks
Specifications
| Brand | Valiant Power |
|---|---|
| Model | VP-PDU-30A-1U-8009 |
| Type | Power Distribution Units |
| Rack Size | 1U |
| Rack Mounting Kit | Standard 19inch |
| Certifications | ETL |
| ROHS | Yes |
| Package Includes | Cage Nuts |
| Input Voltage | 200 - 240V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 30A |
| Input Connector(s) | L6-30p |
| Cord Length | 10 ft |
| Output Voltage | 200-240V |
| Output Watts (VA) | 7500 Watts |
| Output Connector(s) | 10 C13 / 2 C19 |
| Overload Protection | Two 20A circuit breakers protect 6 outlets each |
| Operating Relative Humidity | 5 - 95% |
| Storage Temperature | -15 - 50 Celsius degree \ 5 to 122 degree Fahrenheit |
| Features | - 20kA SURGE SUPPRESSION - DESIGNED FOR DATA CENTER & IT ENVIRONMENTS - 10FT L6-30P LOCKING POWER CORD - HIGH-DENSITY C13 & C19 OUTLET MIX - REAL-TIME POWER MONITORING - BUILT-IN CIRCUIT BREAKER PROTECTION - COMPACT 1U RACK-MOUNT DESIGN - COMMERCIAL-GRADE QUALITY |
| Dimensions | 19.0 × 1.75 × 3.7 in |
| Weight | 5.5 lbs |
Questions about this item
How much rack space and which mounting kit does the 1U PDU require?
It occupies a single 1U slot and includes a standard 19‑inch mounting kit with cage nuts for quick installation.
What input connector and cord length must be accommodated during installation?
The unit ships with a 10‑foot L6‑30P locking cord; verify your facility provides a matching 200‑240V 30A receptacle before mounting.
Which protective components may need replacement after an overload or surge event?
Two 20A circuit breakers protect the outlet banks and can be reset; the 20kA surge suppression module is non‑user‑replaceable and would require unit replacement if sacrificed.