Measures DC voltage from 0 to 5 V with 1.5 class accuracy and a clear, tunable scale for panel mounting
- TypeHI - Test & Measurement Tools
- Measures DC 0-5V with 1.5 class accuracy
- Clear scale plus fine-tuning button for precise reading
- Compact 100 x 80 x 12 mm panel fits tight spaces
- Mounts on 50 x 36 mm centres using M4 and M3 studs
- Operates from -20 °C to 40 °C with AC 2 kV insulation
Analog DC 0–5 V panel voltmeter
This analog panel voltmeter measures DC voltage from 0 to 5 V with 1.5 class accuracy. It is intended for technicians and hobbyists who need a direct-reading instrument for low-voltage DC circuits. The clear scale and fine-tuning button simplify setting the pointer before use.
Panel mounting with M4 and M3 studs
Installation uses two threaded studs: a long M4 × 11 mm and a short M3 × 7.5 mm. The mounting footprint is 50 × 36 mm and the overall depth behind the panel is 48 mm. Ensure the cut-out matches these dimensions; a mismatch is the most common reason the meter will not sit flush.
0–5 V range with 1.5 % accuracy class
The meter comfortably handles DC voltages up to 5 V within its stated 1.5 class accuracy. Readings beyond 5 V exceed the scale and the accuracy guarantee no longer applies. The operating temperature range of –20 °C to 40 °C defines the environmental limits for reliable indication.
Highlights
- Measures DC 0-5V with 1.5 class accuracy
- Clear scale plus fine-tuning button for precise reading
- Compact 100 x 80 x 12 mm panel fits tight spaces
- Mounts on 50 x 36 mm centres using M4 and M3 studs
- Operates from -20 °C to 40 °C with AC 2 kV insulation
Specifications
| Brand | Unique Bargains |
|---|---|
| Type | HI - Test & Measurement Tools |
Questions about this item
How can I confirm the meter reads correctly after wiring it?
Apply a known DC voltage within the 0-5 V range and verify the needle shows the same value within the 1.5 class tolerance.
What ships with the voltmeter and what must I source myself?
The box contains the analog voltmeter and several mounting parts; you must supply the panel cut-out, wiring and a DC source.
Which accuracy class should I choose for general DC monitoring?
The 1.5 class version gives a ±1.5 % of full-scale error, suitable for typical panel monitoring tasks.