Unique-Bargains
Unique-Bargains 85L1 AC 0-50A Analog Panel Ammeter Measurement Tool
Measures AC current from 0 to 50 A with 2 A graduation and a 2.5 % error margin in a 64 x 56 x 48 mm panel-mount housing
- TypeAnalog Multimeters
- Measures AC current up to 50 A
- 2 A graduation for clear reading steps
- Accuracy class 2.5 with ±2.5 % error margin
- Compact 64 x 56 x 48 mm panel footprint
- Lightweight 95 g design with bolts and screws included
Product Identity
The Unique-Bargains 85L1 is an analog panel ammeter designed for AC current measurement from 0 to 50 amperes. It features a 2 ampere graduation scale and a 2.5 accuracy class with a ±2.5% error margin. The unit requires an external current transformer for operation and mounts via supplied bolts and screws.
Suitability
This meter suits technicians and hobbyists needing a direct-reading analog gauge for panel installation in AC circuits up to 50A. It is not for users who require digital readouts, data logging capabilities, or measurement of DC current. Buyers without access to a compatible current transformer should look elsewhere.
Sustained Operation
Under continuous load the analog movement provides stable needle indication without the sampling delay found in digital alternatives. The 95 gramme mechanism and 64mm by 56mm by 48mm case dimensions allow straightforward panel integration. Accuracy remains within the stated 2.5% class across the full operating range.
Highlights
- Measures AC current up to 50 A
- 2 A graduation for clear reading steps
- Accuracy class 2.5 with ±2.5 % error margin
- Compact 64 x 56 x 48 mm panel footprint
- Lightweight 95 g design with bolts and screws included
Specifications
| Brand | Unique Bargains |
|---|---|
| Type | Analog Multimeters |
Questions about this item
What external component is required for the 85L1 ammeter to measure AC current up to 50A?
A current transformer (CT) is required for the 85L1 to function; the meter itself does not measure current directly without one.
Will the 85L1 fit in a panel cut-out designed for a 64 mm by 56 mm front face?
Yes, the front panel measures 64 mm by 56 mm, matching that cut-out size exactly.
How can I verify the 85L1 is reading correctly after wiring it with a CT?
Apply a known AC load within the 0–50 A range; the needle should indicate the expected value within the ±2.5 % accuracy class.