Turck
Turck NI15-P30-Y1 10098 inductive sensor M30×1.5 15mm NAMUR
M30×1.5 inductive sensor with 15 mm switching distance, NAMUR output and ATEX approvals for hazardous areas
- TypeTest Equipment
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- 15 mm sensing range for reliable detection
- NAMUR output per DIN EN 60947-5-6 for safe integration
- ATEX and SIL2 approvals for hazardous-area use
- PA12-GF30 housing resists chemicals and impact
- M30 × 1.5 threaded barrel simplifies mounting
Turck M30×1.5 NAMUR sensor
The Turck NI15-P30-Y1 is a NAMUR inductive sensor built for hazardous-area detection. Its M30×1.5 threaded barrel fits standard process mounts. The 15 mm switching distance suits metal-target presence checks. Electricians and instrument technicians use it for safety-related monitoring.
PA12-GF30 housing runs cool without fan
The plastic PA12-GF30 body dissipates heat passively during continuous DC operation. Nominal 8.2 VDC supply keeps power draw low and produces no audible noise. Non-flush mounting avoids metal-body eddy-current losses. ATEX and SIL2 ratings confirm safe thermal behaviour in classified zones.
135 g cable unit installs in tight glands
The 135 g sensor ships with integral cable for direct termination. M30×1.5 thread seals in cable glands without extra adapters. Non-flush design demands clear space in front of the sensing face. DIN EN 60947-5-6 output simplifies intrinsic-safe barrier wiring.
Highlights
- 15 mm sensing range for reliable detection
- NAMUR output per DIN EN 60947-5-6 for safe integration
- ATEX and SIL2 approvals for hazardous-area use
- PA12-GF30 housing resists chemicals and impact
- M30 × 1.5 threaded barrel simplifies mounting
Specifications
| Brand | TURCK |
|---|---|
| Model | NI15-P30-Y1 10098 |
| Type | Test Equipment |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
How do I mount the M30 × 1.5 threaded barrel without damaging the PA12-GF30 housing?
Screw the sensor into a matching M30 × 1.5 thread by hand until the barrel seats, then tighten with a strap wrench on the plastic flats only — metal jaws on the PA12-GF30 housing will crack it.
What part of the NAMUR sensor will need replacement first in a dusty environment?
The 2‑wire cable entry is the only wear point; grit that works past the gland corrodes the conductors, so plan to swap the cable assembly when insulation resistance drops.
At what point does the 15 mm switching distance become unreliable during continuous operation?
When the target temperature pushes the sensor body past its rated range, the 15 mm rated distance drifts first — the NAMUR current plateau narrows and the PLC sees false trips.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.