Turck
Turck NI15-M30-LIU 1535300 Inductive sensor M30×1.5 15-30 VDC 0-10 V 0-20 mA
M30×1.5 inductive sensor with 0-10 V and 0-20 mA analog outputs on a 15-30 VDC supply
- TypeTest Equipment
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- Measures up to 12 mm for reliable detection
- Dual 0…10 V and 0…20 mA outputs suit varied control systems
- Operates on 15…30 VDC for broad power compatibility
- M30 × 1.5 chrome-plated brass housing resists harsh environments
- Non-flush mounting allows flexible installation in metal surrounds
M30 threaded inductive sensor
The Turck NI15-M30-LIU is a non-flush mount inductive sensor built into a chrome-plated brass M30×1.5 threaded barrel. It operates on 15–30 VDC and provides simultaneous 0–10 V and 0–20 mA analog outputs. A four-wire cable exits the housing for direct connection. The sensor weighs 198 g and carries order number 1535300.
Use-case fit
This unit suits applications that need a continuous analog signal proportional to target distance within a 12 mm measuring range. It is not suited for tasks requiring a simple on/off switching output or a flush-mount form factor. Installations that demand a connector-based electrical interface instead of a flying lead should look elsewhere.
Deciding specification
The defining parameter is the dual analog output delivering both 0–10 V and 0–20 mA from a single device. If the control system accepts only one signal type or requires a digital switching output, this sensor will not match the input requirements.
Highlights
- Measures up to 12 mm for reliable detection
- Dual 0…10 V and 0…20 mA outputs suit varied control systems
- Operates on 15…30 VDC for broad power compatibility
- M30 × 1.5 chrome-plated brass housing resists harsh environments
- Non-flush mounting allows flexible installation in metal surrounds
Specifications
| Brand | TURCK |
|---|---|
| Model | NI15-M30-LIU 1535300 |
| Type | Test Equipment |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
What supply voltage must I already provide for the NI15-M30-LIU to operate?
The sensor requires a DC supply between 15 V and 30 V to power its analog output stage.
Will the 12 mm non-flush sensing range still detect targets when mounted beside older M30 flush-mount sensors?
Yes, the 12 mm non-flush range works independently; adjacent flush sensors do not reduce its detection distance.
How can I verify the sensor is working after wiring the 4-wire cable?
Measure the output — it should deliver 0…10 V and 0…20 mA proportional to target position within the 12 mm range.