We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Turck

Turck FDNP-S0808G-WW 8 PNP Inputs 8 Outputs 0.5A IP67 DeviceNet I/O Module

SKU CH-WPTB-2YJ23 MPN FDNP-S0808G-WW

DeviceNet I/O module with eight PNP inputs and eight 0.5 A outputs in an IP67 housing

  • TypeTest Equipment
  • Item Count1 pack
  • Selling UnitBox
  • Parts3 Years
  • Labor1 Year
  • 8 PNP inputs simplify sensor wiring
  • 8 outputs at 0.5 A drive actuators directly
  • IP67 rating withstands harsh environments
  • DeviceNet fieldbus enables industrial communication
  • Fibre-glass reinforced PA6 housing resists vibration and shock

DeviceNet I/O module with 8 PNP inputs

The Turck FDNP-S0808G-WW is a compact DeviceNet I/O module that provides eight digital PNP inputs and eight digital outputs rated at 0.5 A each. It connects via M12 connectors with two channels per connector and includes a separate actuator power supply. The module is built for industrial networks that use the DeviceNet protocol.

Suited for IP67 machine-level I/O.

This module suits engineers who need rugged, machine-mounted I/O with IP67 protection, vibration and shock resistance, and an operating range from -25 °C to 70 °C. It is not intended for buyers who require cabinet-mounted I/O with a lower protection class, or for applications that demand more than eight input channels or eight output channels.

8 digital PNP inputs and 8 outputs at 0.5

The defining specification is the combination of eight PNP inputs and eight 0.5 A outputs on a single DeviceNet node. If the application requires a different channel count, a different output current, or a different fieldbus, this module will not match the design.

Highlights

  • 8 PNP inputs simplify sensor wiring
  • 8 outputs at 0.5 A drive actuators directly
  • IP67 rating withstands harsh environments
  • DeviceNet fieldbus enables industrial communication
  • Fibre-glass reinforced PA6 housing resists vibration and shock

Specifications

BrandTURCK
ModelFDNP-S0808G-WW 6603326 I/O
TypeTest Equipment
Item Count1 pack
Selling UnitBox
Parts3 Years
Labor1 Year

Questions about this item

What M12 connector count and pin arrangement does the FDNP-S0808G-WW need for its 8 PNP inputs and 8 outputs?

The module uses M12 connectors with two channels per connector, so eight connectors handle all sixteen digital points while the separate actuator supply feeds the 0.5 A outputs.

Which wiring step is most often missed when commissioning this DeviceNet I/O module?

Installers frequently forget to connect the separate actuator power supply, leaving the eight 0.5 A outputs without voltage even though the DeviceNet bus and input side are live.

How often should the fibre-glass reinforced PA6 housing seals be inspected to maintain the IP67 rating?

Inspect the housing seals at least once a year and after any severe vibration or shock event; the encapsulated electronics and metal connectors are maintenance-free, but seal integrity keeps the IP67 protection valid.